5. Maintenance
1.The appliance area should be kept clear and free from combustible materials, gasoline and other
flammable vapors, and liquids.
2. The flow of combustion and ventilation air must not be obstructed.
3. Your Super Saver XL
TM
Heater should be inspected before each use, and at least annually by a
qualified service person.
4. The hose should be visually inspected prior to each use of the heater. If it is evident there is excessive
abrasion or wear or the hose is cut, it must be replaced prior to the heater being put into operation.
The replacement hose assembly shall be that specified by the manufacturer. (Refer to parts list on
.)
5. Inspect heater and gas connections periodically for gas leaks with an approved gas leak testing
solution; applying a soapy water mixture to gas connections works well. Bubble formation indicates
a leak.
6. Keep heater clean at all times.
a. Open doors and blow out dust with high pressure air hose. Be sure interior of burner and flared
end are kept clean.
b. Burner orifice and pilot ignition assembly must be kept clean and free of carbon build-up.
c. Check blower wheel regularly for dust accumulation and clean periodically for maximum airflow.
d. Thermostat coils must be kept clean to assure proper temperature control.
e. Pilot assembly must be cool before wash-down. Do not operate heater for one hour following
wash-down.
DISCLAIMER
This appliance rating is based on the use of ANSI LC-2 test gases including LP (2500 BTU/ft
3
,
93.15 MJ/m
3
) and natural gas (1075 BTU/ft
3
, 40 MJ/m
3
). Cumberland makes no guarantees regarding
the proper operation of this appliance when these conditions are not met.