4. User Instructions
4801-1020
Super-Saver XL
TM
Heater
17
Variable Heat Output Adjustment
1. Some models of propane (LP) gas or natural gas heaters have a throttle valve (1) located between
the gas control valve (2) and gas manifold assemblies (3) which is used for varying the heat output.
NOTE
:
THIS IS NOT A MANUAL GAS CUT OFF VALVE.
2. The throttle valve (1) can be adjusted to deliver either minimum heat or maximum heat. When the
throttle valve handle is parallel to the gas flow, the valve is completely open to deliver maximum heat
output. Refer to
. The throttle valve (1) may be adjusted to minimum heat output by turning
the handle 90° to the gas flow or any position between the maximum and minimum settings.
Refer to
.
Figure 4C
Figure 4D
Ref #
Description
1
Throttle Valve
2
Gas Control Valve
3
Gas Manifold
Maximum Heat
Minimum Heat
90% of Maximum
75% of Maximum