background image

4801-1020

Super-Saver XL

TM 

Heater

Agricultural Building Heater 120V, 60 Hz, ETL

Owner’s Manual

4801-1020

Version: 4.0

Date: 05-08-19

Содержание Super-Saver XL HH-SS-120-XL

Страница 1: ...4801 1020 Super Saver XLTM Heater Agricultural Building Heater 120V 60 Hz ETL Owner s Manual 4801 1020 Version 4 0 Date 05 08 19...

Страница 2: ...os and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make changes at any time without notice Standing Pilot Ignition W...

Страница 3: ...4 Installing the Dual Flare Duct 14 Connecting the Gas Supply 14 Chapter 4 User Instructions 15 Connecting Electrical Power 15 Start Up 15 Shutting OFF Heater 16 Variable Heat Output Adjustment 17 Cha...

Страница 4: ...y out of the work area at all times Alterations must not be made to the equipment Alterations can produce dangerous situations resulting in SERIOUS INJURY or DEATH This equipment must be installed in...

Страница 5: ...is symbol indicates an imminently hazardous situation which if not avoided will result in serious injury or death This symbol indicates a potentially hazardous situation which if not avoided can resul...

Страница 6: ...ly a fire or explosion can result causing property damage personal injury or loss of life Carefully read all safety messages in this manual and safety signs on your machine Keep signs in good conditio...

Страница 7: ...each use and at least annually by a qualified service person Be aware that the heater may operate under automatic control and may start without warning Do not service the heater without first disconne...

Страница 8: ...n result in electric shock personal injury or death If permanently connected to power supply make sure a circuit breaker or similar cutoff device is provided to permit disconnection of power for servi...

Страница 9: ...The equipment shall be installed in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Check all connections for gas leaks Do not operate heater with door open or panels Do not move or ha...

Страница 10: ...e the heater in spaces which contain or may contain volatile or airborne combustibles or products such as gasoline solvents paint thinner dust particles or unknown chemicals Failure to follow these in...

Страница 11: ...n Off Sheet Below is a sign off sheet that can be used to verify that all personnel have read and understood the safety instructions This sign off sheet is provided for your convenience and personal r...

Страница 12: ...it is operating hot or connected to power supply 8 Turn power OFF before servicing Heater may start at any time if power is connected 9 Heater is not recommended for heating human living quarters 10 N...

Страница 13: ...ge 14 Specifications and Requirements NOTE Refer to heater ratings plate for unit voltage amperage and frequency ratings Models 250K BTU Universal Mount Weight 153 lbs Height 32 81 cm Width 27 1 2 70...

Страница 14: ...a carpenter s level to check that the heater is level Installing the Dual Flare Duct Fold Dual Flare duct 1 to shape as shown in Figure 3A Install Dual Flare duct to heater exhaust as shown with sheet...

Страница 15: ...ore turning ON gas verify that the main supply valve is open Check all connections for leaks with a soap and water gas leak testing solution Verify the gas valve knob is in the ON position If not turn...

Страница 16: ...Danger label listed under Acceptable Pressures on the outside of the heater This should be done only by a qualified gas installer Operating the heater at a pressure too high or too low will adversely...

Страница 17: ...valve 1 can be adjusted to deliver either minimum heat or maximum heat When the throttle valve handle is parallel to the gas flow the valve is completely open to deliver maximum heat output Refer to...

Страница 18: ...for gas leaks with an approved gas leak testing solution applying a soapy water mixture to gas connections works well Bubble formation indicates a leak 6 Keep heater clean at all times a Open doors a...

Страница 19: ...4801 1020 Super Saver XLTM Heater 19 6 Wiring Diagrams SPI Model Component and Wiring Diagram...

Страница 20: ...6 Wiring Diagrams SPI Model 20 4801 1020 Super Saver XLTM Heater Ladder Type Schematic Diagram...

Страница 21: ...time required to troubleshoot this system 1 Turn OFF the gas supply at the main gas valve 2 Disconnect electric power to the system at the main fuse of the circuit breaker if connected 3 Visually ins...

Страница 22: ...ngth from meter to most remote heater length from a to e or g 100 30 m 25 8 m 125 38 m Minor loss equivalents from Table 1 1 gate valve x 2 valve 1 m valve 3 tees x 11 tee 4 m tee 35 13 m Calculated E...

Страница 23: ...Gate valve 4 Gas Meter Minor Loss Equivalents Fitting 2 5 08 cm IPS or Smaller 2 5 08 cm IPS to 4 10 16 cm IPS Feet per Fitting Meters per Fitting Feet per Fitting Meters per Fitting 45 Elbow 3 1 5 2...

Страница 24: ...0 1 1 4 1 380 1400 950 770 660 580 530 490 460 430 400 325 280 219 206 1 1 2 1 610 2100 1460 1180 990 900 810 750 690 650 620 500 430 325 309 2 2 067 3950 2750 2200 1900 1680 1520 1400 1300 1220 1150...

Страница 25: ...eplacement parts When ordering service parts please specify the country model number date of manufacture voltage frequency gas type inside or outside mount and whether the heater is constructed of gal...

Страница 26: ...9 Parts List 26 4801 1020 Super Saver XLTM Heater 250K BTU SPI Continued NOTE The parts pointed out on this page are listed on Page 30...

Страница 27: ...9 Parts List 4801 1020 Super Saver XLTM Heater 27 250K BTU SPI Continued NOTE The parts pointed out on this page are listed on Page 30...

Страница 28: ...9 Parts List 28 4801 1020 Super Saver XLTM Heater 250K BTU SPI Continued NOTE The parts pointed out on this page are listed on Page 30...

Страница 29: ...9 Parts List 4801 1020 Super Saver XLTM Heater 29 250K BTU SPI Continued NOTE The parts pointed out on this page are listed on Page 30...

Страница 30: ...ot Lite 1 1 4 x 2 22 3004 0120 S Gas Valve HW Pilot LP with Silicone Added 3004 0121 S Gas Valve HW Pilot NG with Silicone Added 23 2000 0001 HH Tubing ASTM B280 Formed 23 5 16 24 1009 1500 Valve Bron...

Страница 31: ...n behalf of a claimant without prior written authorization from the GSI warranty department shall not be reimbursed This warranty is not transferable and applies only to the original end user GSI shal...

Страница 32: ...des and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E Illinois St Assumption IL 62510...

Отзывы: