45
PNEG-1096 Ladder, Safety Cage, & Platforms
4.00 INSIDE STIFFENED
Inside Ladder
INSIDE OF GRAIN BIN
INSIDE LADDER PLACEMENT
The inside ladder package includes the lad-
ders and double the amount of standoffs.
Begin by positioning the ladder directly un-
der the manhole roof panel and place the
standoffs every 22" vertically on the sidewall
sheets using the horizontal seam holes for
every other hole location. Us 5/16" x 3/4" bin
bolts to attach the standoffs to the sidewall
of the grain bin. Refer to the diagram on the
right.
LS-121 LADDER
STANDOFFS
22" TYP.
18.3/4"
REV. 5-25-95
INSIDE LADDER STANDOFFS REQUIREMENTS
Field drilling will be necessary for the standoffs located in
the middle of the sidewall sheet. Drill 2 holes 3/8" diameter
directly in line with the horizontal seam holes 18 3/4" apart.
Continue down the sidewall with standoffs at every 22"
spacing. Refer to the diagrams at the left.
Manway Sheet