background image

Part No. 4801-5309 Rev 1-15 

Owners Manual 

Evolution Back-Up 

 

CUMBERLAND            

Assumption, IL 62510         • Phone 217-226-4421           • Fax 217-226-4420

 

 
 
 
 
 

Evolution Back-Up 

 

 

Cumberland 

1004 E. Illinois St. 

Assumption, IL 62510 

Содержание Evolution Back-Up

Страница 1: ...Part No 4801 5309 Rev 1 15 Owners Manual Evolution Back Up CUMBERLAND Assumption IL 62510 Phone 217 226 4421 Fax 217 226 4420 Evolution Back Up Cumberland 1004 E Illinois St Assumption IL 62510...

Страница 2: ...ctions 6 7 1 Toggle Sequence of Mode Button 6 7 2 Checking Adjusting Temperatures and Settings 6 8 Set Limits 6 9 Program Mode Parameters 7 10 Calibrate Sensors 7 10 1 Installation 8 10 2 Unpacking Co...

Страница 3: ...switch position 50 60 Hz Room Temperature must be between 32 F 0 C and 122 F 50 C 2 Warnings Warning When this controller is used in a life support heating and ventilation system where failure could...

Страница 4: ...nces These modes are Normal Operation Emergency Operation and Override Operation These modes will be explained in more detail below These modes are entered based on information that it has received or...

Страница 5: ...lay is also engaged in this mode of operation 4 4 Fail Safe Relay Operation There are two types of Relay strips used in the Evolution 3000 The Normally Open NO strip requires a signal from the control...

Страница 6: ...en use the button to increase the value and the button to decrease the value Room Temperature The average of the sensors located inside the house High Limit The temperature inside the house at which t...

Страница 7: ...Table 1 10 Calibrate Sensors The temperature sensors should be calibrated to ensure accurate temperature detection To calibrate the sensors an independent temperature measurement is required such as...

Страница 8: ...11 2 6 Wire the power supply See Section 11 4 7 Wire the Back Up to the EV 3000 See Wiring Diagrams at the back of this manual 8 Wire the Local Network connection 9 Connect the PowerTrak to the Overri...

Страница 9: ...f 17 11 Wiring Diagrams 11 1 Evolution Back Up Assembly Alarm Connections Sensor Connections Tunnel Override Settings Vent Override Settings Backup Connections to Evolution Voltage Selector Switch Pow...

Страница 10: ...Connection to Enable Sensor 2 Inset B Sensor 1 2 Connections Sensor 2 Enabled Installed Enabled Vacant Disabled Jumper NOTE Tape Shields to Prevent Damage Inset C Back Up Alarm Connection Internal Wir...

Страница 11: ...o pull curtain up to open then reverse wires connected to Open and Close terminals Inset A Vents Override Evolution Back Up Circuit Board PowerTrak Inset A Vent Override To EV 3000 Cont Hot PT Hot PT...

Страница 12: ...000 16 Stage Expansion Module Evolution 3000 Cabinet INSET A Inset A AC input on PCB 171 External GND Hot Neutral External GND Hot Neutral External GND Hot Neutral External GND Hot Neutral AC Junction...

Страница 13: ...pansion units Back up Local Network Local Network Back up Local network Harness In Expansion Backup Green Red Red Green White Shield Black White Shield Black Black White White Black Orange Orange Gree...

Страница 14: ...42 4 5 8 12 493 68 20 6 836 93 33 9 24 055 43 6 1 12 325 68 5 20 3 6 779 93 4 34 1 23 82 43 3 6 3 12 215 68 9 20 5 6 695 93 9 34 4 23 472 43 9 6 6 12 051 69 4 20 8 6 612 94 5 34 7 23 13 44 4 6 9 11 9...

Страница 15: ...a shorted sensor wire Check sensor resistance E2 Sensor 2 Error Usually indicates a shorted sensor wire Check sensor resistance Note If Sensor 2 is switched OFF then this error code is not active E3...

Страница 16: ...ons and Limitations THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH ABOVE SPECIFICALLY GSI MAKES NO FURTHER WARRANTY OF ANY KIND EXPRESS OR IMPLIED INCLUDING WITH...

Страница 17: ...Part No 4801 5309 rev 1 15 Evolution Back Up 17 of 17...

Отзывы: