background image

1. Safety

PNEG-1559

 Competitor Series - Fiberglass Fans

5

Safety Instructions

Our foremost concern is your safety and the safety of others associated with this equipment. We want to 
keep you as a customer. This manual is to help you understand safe operating procedures and some 
problems that may be encountered by the operator and other personnel.

As owner and/or operator, it is your responsibility to know what requirements, hazards, and precautions 
exist, and to inform all personnel associated with the equipment or in the area. Safety precautions may be 
required from the personnel. Avoid any alterations to the equipment. Such alterations may produce a very 
dangerous situation where SERIOUS INJURY or DEATH may occur.

This equipment shall be installed in accordance with the current installation codes and applicable 
regulations, which should be carefully followed in all cases. Authorities having jurisdiction should be 
consulted before installations are made.

Install and Operate Electrical Equipment Properly

Electrical controls should be installed by a qualified electrician and 
must meet the standards set by the National Electrical Code and all 
local and state codes.

Disconnect and lock out all power sources before installing 
wires/cables or servicing equipment.

Electric Shock Hazard

Rotating Fan Blade

Keep Hands Away from Moving Parts

DO NOT put hand or arm in fan. Rotating parts can crush 
and dismember.

DO NOT put any kind of tool inside fan to try and clear debris 
while the fan is running. Damage to the equipment will result.

ALWAYS turn OFF and lock out all power sources before 
servicing equipment.

Lifting Hazard

Single person lift could cause injury.

Use two or more people or a mechanical lifting device 
to lift/move heavy equipment.

Use Assistance When Lifting
or Moving Heavy Equipment

Содержание Competitor PNEG-1559

Страница 1: ...PNEG 1559 Competitor Series Fiberglass Fans Installation and Operation Manual PNEG 1559 Date 07 25 13...

Страница 2: ...nstallation methods and operation of the fan FEATURES 30044 CFM and 20 2 CFM W at 0 05 on 54 high performance Limited lifetime warranty on the housing and cone Corrosion resistant Easy assembly and ma...

Страница 3: ...rical Wiring 15 Electrical Hook Up 15 54 3 Phase 50 Hz CE Electrical Hook Up 16 Chapter 5 Start Up and Maintenance 17 Start Up and Operation of the Competitor Series Fan 17 Chapter 6 Troubleshooting G...

Страница 4: ...nd its safety instructions is a misuse of the equipment and may lead to serious injury or death DANGER WARNING CAUTION NOTICE DC 2180 This is the safety alert symbol It is used to alert you to potenti...

Страница 5: ...and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made Install and Operate Electrical Equipment Pr...

Страница 6: ...he job Remove all jewelry Tie long hair up and back Wear safety glasses at all times to protect eyes from debris Wear gloves to protect your hands from sharp edges on plastic or steel parts Wear steel...

Страница 7: ...and may lead to dangerous situations This fan is not designed for use in atmospheres where the risk of explosion is foreseen Such environments may include enclosed areas of high dust concentrations g...

Страница 8: ...type fuse must be used A safety cut off switch should be located adjacent to each fan Contact your local distributor for the correct cut off switch The motor must be securely and adequately grounded...

Страница 9: ...TAY CLEAR OF ROTATING BLADE May cause serious injury Blade may start automatically Disconnect and lockout power sources before servicing FLYING OBJECTS HAZARD Danger of eye injury Wear eye protection...

Страница 10: ...STAY CLEAR OF ROTATING BLADE May cause serious injury Blade may start automatically Disconnect and lockout power sources before servicing FLYING OBJECTS HAZARD Danger of eye injury Wear eye protection...

Страница 11: ...ervicing DC 995 WARNING DC 995 2 0 x 4 1 2 WARNING Shear Point Located left middle outside and right middle inside Lockout power before servicing HIGH VOLTAGE Will cause serious injury or death STAY C...

Страница 12: ...the opening from the inside Using a minimum of two 2 people lift fan housing into the opening 3 Check the fan for vertical position before screwing flanges down Fasten flanges to framework with the w...

Страница 13: ...3 Installation and Assembly PNEG 1559 Competitor Series Fiberglass Fans 13 Fan Dimensions Figure 3B...

Страница 14: ...ition onto the fan housing Push completely onto orifice and line up the inner holes of the orifice with the holes of the cone Bolt the cone to the housing orifice using eight 8 5 16 SS flange bolts ei...

Страница 15: ...d wire should be located on the L2 connection as depicted If this is not the case switch the Red and Black wires Refer to the wiring diagram on the side of the motor for correct wiring for 115V and 23...

Страница 16: ...supplied 3 Motor contactor not supplied with fused control voltage via fan control switch or control system not supplied 4 Motor overload breaker not supplied 5 Service disconnect not supplied Figure...

Страница 17: ...s of service Take note of the belt position in the pulleys make sure it is slightly raised or flush with the pulley If recessed into the grooves replace the belt b The motor and shaft bearings are lub...

Страница 18: ...t guards clogged by dirt debris Voltage supplied is not correct must be within 10 of the nominal voltage Repair replace clean as necessary Repair replace clean as necessary Check line voltage at motor...

Страница 19: ...eries Fiberglass Fan CS54C1 P and CS54C1 P BLK See Pages 24 and 25 4 54 Competitor Series Fiberglass Fan CS5435 E NC CE See Pages 26 and 27 5 54 Competitor Series Fiberglass Fan CS5435 P NC CE See Pag...

Страница 20: ...7 Parts List 20 PNEG 1559 Competitor Series Fiberglass Fans 24 Competitor Series Fiberglass Fan CS24C1 and CS24C1 BLK...

Страница 21: ...APP 24 Fan PTD White 1 7 13 0147 Propeller 5 Blade Torque Decal Attached 1 7 10 0097 Shutter Mount Hardware 1 7 91 0042 Button Turn Plastic Large Tongue 8 7 FH 1309 Lock Nut 1 2 with Pipe Threads 1 7...

Страница 22: ...7 Parts List 22 PNEG 1559 Competitor Series Fiberglass Fans 36 Competitor Series Fiberglass Fan CS36C1...

Страница 23: ...rip 2 6 13 0148 Propeller X Blade X Diameter Competitor Series 36 1 7 12 0093 Cone APP 36 Fiberglass Discharge 1 7 10 0105 Fiberglass Fan Shutter Mount Hardware 10 7 91 0042 Turn Button Plastic Large...

Страница 24: ...7 Parts List 24 PNEG 1559 Competitor Series Fiberglass Fans 54 Competitor Series Fiberglass Fan CS54C1 P and CS54C1 P BLK...

Страница 25: ...s Cone Guard Hardware Kit 1 14 S 7447 Flange Bolt 5 16 18 x 1 SS Full Thread 20 14 S 8452 Flange Nut 5 16 18 SS Waxed 20 14 S 8724 Fender Washer 5 16 x 1 1 2 x 1 16 SS 40 14 DC 1540 Decal Danger Warni...

Страница 26: ...7 Parts List 26 PNEG 1559 Competitor Series Fiberglass Fans 54 Competitor Series Fiberglass Fan CS5435 E NC CE...

Страница 27: ...14 10 0100 54 Fiberglass Cone Guard Hardware Kit 1 14 S 7447 Flange Bolt 5 16 18 x 1 SS Full Thread 20 14 S 8452 Flange Nut 5 16 18 SS Waxed 20 14 S 8724 Fender Washer 5 16 x 1 1 2 x 1 16 SS 40 14 DC...

Страница 28: ...7 Parts List 28 PNEG 1559 Competitor Series Fiberglass Fans 54 Competitor Series Fiberglass Fan CS5435 P NC CE...

Страница 29: ...ite 1 14 10 0100 54 Fiberglass Cone Guard Hardware Kit 1 14 S 7447 Flange Bolt 5 16 18 x 1 SS Full Thread 20 14 S 8452 Flange Nut 5 16 18 SS Waxed 20 14 S 8724 Fender Washer 5 16 x 1 1 2 x 1 16 SS 40...

Страница 30: ...7 Parts List 30 PNEG 1559 Competitor Series Fiberglass Fans 54 Competitor Series Fiberglass Fan CS54C35 E CE...

Страница 31: ...14 10 0100 54 Fiberglass Cone Guard Hardware Kit 1 14 S 7447 Flange Bolt 5 16 18 x 1 SS Full Thread 20 14 S 8452 Flange Nut 5 16 18 SS Waxed 20 14 S 8724 Fender Washer 5 16 x 1 1 2 x 1 16 SS 40 14 DC...

Страница 32: ...7 Parts List 32 PNEG 1559 Competitor Series Fiberglass Fans 54 Competitor Series Fiberglass Fan CS54C35 P CE...

Страница 33: ...te 1 14 10 0100 54 Fiberglass Cone Guard Hardware Kit 1 14 S 7447 Flange Bolt 5 16 18 x 1 SS Full Thread 20 14 S 8452 Flange Nut 5 16 18 SS Waxed 20 14 S 8724 Fender Washer 5 16 x 1 1 2 x 1 16 SS 40 1...

Страница 34: ...7 Parts List 34 PNEG 1559 Competitor Series Fiberglass Fans 54 Competitor Series Fiberglass Fan CS54C1 E...

Страница 35: ...100 54 Fiberglass Cone Guard Hardware Kit 1 14 S 7447 Flange Bolt 5 16 18 x 1 SS Full Thread 20 14 S 8452 Flange Nut 5 16 18 SS Waxed 20 14 S 8724 Fender Washer 5 16 x 1 1 2 x 1 16 SS 40 14 DC 1540 De...

Страница 36: ...36 PNEG 1559 Competitor Series Fiberglass Fans NOTES...

Страница 37: ...AR PURPOSE OR DESIGN OF SUCH PRODUCTS GSI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole...

Страница 38: ...applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E Illinois St Assumption IL 62510 0020 Ph...