background image

8887119 

1/6 HP Portable Submersible Sump Pump 

V1.0 

For technical questions call 1-800-665-8685 

4. 

Avoid running the pump for more than 10 minutes at a time. 

5. 

If the pump becomes air locked, shut the power off for approximately 1 
minute then restart the pump. Repeat several times to clear the air 
from the pump. 

CARE & MAINTENANCE 

WARNING! Do not dissassemble the pump. There are no serviceable 
internal parts. Dissassembly may damage the pump and cause a leak or 
electrical hazard.  

1. 

Maintain the tool with care. A tool in good condition is efficient, easier 
to control and will have fewer problems. 

2.  Make certain that the power source conforms to the requirements of 

your equipment. 

3. 

Always disconnect the pump from the power source prior to repairs. 
Always reconnect the pump to the power source after the repairs. 

4. 

Only use accessories intended for use with this tool. 

5. 

Maintain the tool’s labels and name plates. These carry important 
information. If unreadable or missing, contact Princess Auto Ltd. for 
replacements. 

WARNING! Only qualified service personnel should repair the tool. An 
improperly repaired tool may present a hazard to the user and/or others. 

CLEANING 

Rinse with clean water. Remove stubborn contamination with a brush and 
detergent. Submerge the pump in a container with clean water and switch 
on for a short time to rinse the inside of the pump. 

CLEANING THE SUCTION AREA

 

Clean all accessible insides of the casing. Remove fibers that have wound 
around the rotor shaft by opening the pressure connection. Remove 
stubborn contamination with a brush and detergent. 

NOTE! Before using the pump again, first soak the pump so that any possible 
dirt residues do not block the appliance. 

MAINTENANCE SCHEDULE 

BEFORE EACH USE 

Perform a visual inspection of the pump casing and cables for damage. 

Содержание POWER FIST E230946

Страница 1: ...V1 0 8887119 Please read and understand all instructions before use Retain this manual for future reference...

Страница 2: ...d in this manual A notice is an alert that there is a possibility of property damage injury or death if certain instructions are not followed DANGER This notice indicates an immediate and specific haz...

Страница 3: ...RNING Wear personal protective equipment approved by the Canadian StandardsAssociation CSA or American National Standards Institute ANSI PERSONAL PROTECTIVE EQUIPMENT 1 Always wear impact safety goggl...

Страница 4: ...y or alter this tool or use it for an unintended purpose 5 Do not use the tool if any parts are damaged broken or misplaced Repair or replace the parts 6 Do not run the pump if there is no water in th...

Страница 5: ...National Electrical Code ANSI NFPA 80 1984 or the Canadian Electrical Code 4 Do not allow the plug on the end of the electrical cord to be submerged 5 Do not use extension cords They are a fire hazar...

Страница 6: ...er cord replaced by a qualified service technician 2 Keep all connections dry and off the ground to reduce the risk of electric shock Do not touch plug with wet hands 3 Prevent damage to the power cor...

Страница 7: ...place the pump directly on open earth or gravel 3 Do not use the power cable to carry or hang the pump OPERATION CAUTION Do not operate the pump without a hose 1 Submerge the pump at an angle into th...

Страница 8: ...r the repairs 4 Only use accessories intended for use with this tool 5 Maintain the tool s labels and name plates These carry important information If unreadable or missing contact Princess Auto Ltd f...

Страница 9: ...function properly or parts are missing If unable to do so have a qualified technician service the tool Problem s Possible Cause s Suggested Solution s Pump does not run 1 No power 2 Motor overheats 3...

Страница 10: ...4 The suction opening is blocked 5 The pressure line is kinked 6 The pressure line leaks 1 Reduce the delivery height to the maximum height see Specifications 2 Use a pressure line with a larger diame...

Страница 11: ...1 0 1 6 HP Portable Submersible Sump Pump 8887119 Visit www princessauto com for more information 11 PARTS BREAKDOWN PARTS LIST DESCRIPTION QTY 1 Impeller 1 2 Sealing gasket 1 3 Pump base 1 4 Screen 1...

Страница 12: ...8887119 1 6 HP Portable Submersible Sump Pump V1 0 12 For technical questions call 1 800 665 8685...

Страница 13: ...V1 0 8887119 Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard...

Страница 14: ...st une alerte indiquant qu il existe un risque de dommage la propri t de blessure ou de d c s si on ne respecte pas certaines instructions DANGER Cet avis indique un risque imm diat et particulier qui...

Страница 15: ...et sec Gardez les outils hors de la port e des enfants S CURIT PERSONNELLE AVERTISSEMENT Portez de l quipement de protection personnelle homologu par l Association canadienne de normalisation CSA ou l...

Страница 16: ...cation continue telle qu une fontaine ou une cascade 3 Cette pompe a un moteur rempli d huile et ne doit PAS tre utilis e dans de l eau contenant du poisson 4 Utilisez le bon outil pour la t che effec...

Страница 17: ...ir les br lures lors de l entretien de la pompe laissez la refroidir apr s l arr t avant de la manipuler 20 V rifiez toujours la pompe avant chaque utilisation vitez d utiliser la pompe si elle est en...

Страница 18: ...lev de choc lectrique si votre corps est mis la terre 11 Le fusible doit tre un disjoncteur pr sentant un courant r siduel mesur ne d passant pas 30 mA 12 Si l appareil n est pas utilis assurez vous q...

Страница 19: ...l de l outil pendant son utilisation Le cordon doit toujours se trouver derri re l outil d Tenez le cordon l cart de la chaleur de l huile des rebords coupants ou des pi ces mobiles 4 Veillez ce que p...

Страница 20: ...la terre nue ou sur le gravier 3 N utilisez pas le c ble d alimentation pour transporter ou pour suspendre la pompe UTILISATION ATTENTION vitez que la pompe tourne sur son axe longitudinal 1 Plongez l...

Страница 21: ...proc d la r paration 4 Utilisez seulement des accessoires con us pour tre utilis s avec cet outil 5 Veillez ce que l tiquette et la plaque signal tique demeurent intactes sur l outil Elles comportent...

Страница 22: ...ent boucher l appareil MISE AU REBUT Recyclez votre outil endommag dans une installation pr vue cet effet s il est impossible de le r parer D PANNAGE Si l outil ne fonctionne pas correctement ou si de...

Страница 23: ...est trop bas 1 La hauteur de refoulement est trop lev e 2 Le diam tre de la conduite de pression est trop petit 3 La conduite de pression est obstru e 4 L ouverture d aspiration est obstru e 5 La cond...

Страница 24: ...ard portable et submersible de 1 6 CV V1 0 12 En cas de questions techniques appelez le 1 800 665 8685 R PARTITION DES PI CES LISTE DES PI CES NO DESCRIPTION QT 1 Impulseur 1 2 Joint d tanch it 1 3 Ba...

Отзывы: