8887119
1/6 HP Portable Submersible Sump Pump
V1.0
10
For technical questions call 1-800-665-8685
Problem(s)
Possible Cause(s)
Suggested Solution(s)
The delivery rate
is too low.
1. The delivery height is
too great.
2. The pressure line
diameter is too small.
3. The pressure line is
blocked.
4. The suction opening is
blocked.
5. The pressure line is
kinked.
6. The pressure line leaks.
1. Reduce the delivery height to
the maximum height (see
Specifications).
2. Use a pressure line with a
larger diameter.
3. Remove the blockage.
4. Remove the blockage.
5. Straighten the pressure line.
6. Seal the pressure line, tighten
the threaded connections.
The pump runs
very loudly.
1. The pump is drawing in
air.
1a. Ensure there is sufficient
liquid present.
1b. Keep the pump at an angle
while submerging.