Technical Support: 1-800-721-9243, Monday-Friday, 8:00 a.m. – 4:30 p.m., CST
6
Performance Data - cont.
Organic Chemicals Included by Surrogate Testing:
Applies to US-EZ-4 Only
Substance
Influent Challenge
Concentration mg/L
Maximum permissible product water
concentration mg/L
alachor
0.050
0.001
atrazine
0.100
0.003
benzene
0.081
0.001
carbofuran
0.190
0.001
carbon tetrachloride
0.078
0.0018
chlorobenzene
0.077
0.001
chloropicrin
0.015
0.0002
2,4-D
0.110
0.0017
dibromochloropropane (DBCP)
0.052
0.00002
o-dichlorobenzene
0.080
0.001
p-dichlorobenzene
0.040
0.001
1,2-dichloroethane
0.088
0.0048
1,1-dichloroethylene
0.083
0.001
cis-1,2-dichloroethylene
0.170
0.0005
trans-1,2-dichloroethylene
0.086
0.001
1,2-dichloropropane
0.080
0.001
cis-1,3-dichloropropylene
0.079
0.001
dinoseb
0.170
0.0002
endrin
0.053
0.00059
ethylbenzene
0.088
0.001
ethylene dibromide (EDB)
0.044
0.00002
haloacetonitriles (HAN):
bromochloroacetonitrile
0.022
0.0005
dibromoacetonitrile
0.024
0.0006
dichloroacetonitrile
0.0096
0.0002
trichloracetonitrile
0.015
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
0.0072
0.0001
1,1,1-trichloro-2-propanone
0.0082
0.0003
heptachlor
0.25
0.00001
heptachlor epoxide
0.0107
0.0002
hexachlorobutadiene
0.044
0.001
hexachlorocyclopentadiene
0.060
0.000002
lindane
0.055
0.00001
methoxychlor
0.050
0.0001
pentachlorophenol
0.096
0.001
simazine
0.120
0.004
styrene
0.150
0.0005
1,1,2,2,-tetrachloroethane
0.081
0.001
tetrachloroethylene
0.081
0.001
toluene
0.078
0.001
2,4,5-TP (silvex)
0.270
0.0016
tribromoacetic acid
0.042
0.001
1,2,4-trichlorobenzene
0.160
0.0005
1,1,1-trichloroethane
0.084
0.0046
1,1,2-trichloroethane
0.150
0.0005
trichloroethylene
0.180
0.0010
trihalomethanes (includes):
chloroform (surrogate chemical)
bromoform
0.300
0.015
bromodichloromethane
chlorodibromomethane
xylenes (total)
0.070
0.001
RC-EZ-3 Cartridges
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the
substances listed below. The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance
Influent Challenge
Concentration
Maximum
Permissible
Product Water
Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42
Chlorine
2.0 mg/L±10%
≥
50%
96.2%
97.4%
Particulates
(0.5 to<1µm)-Class I
at least 10,000
particles/mL
≥
85%
99.8%
99.9%
Standard 53
Cyst
Minimum 50,000/L
99.95%
99.95%
99.9%
Turbidity
11 mg/L ± 1 NTU
0.5 NTU
96.4%
98.5%
Lead (pH 6.5)
0.15 mg/L ± 10%
0.010 mg/L
99.3%
99.3%
Lead (pH 8.5)
0.15 mg/L ± 10%
0.010 mg/L
94.8%
98.3%
Atrazine
0.009 mg/L ± 10%
0.003 mg/L
94.1%
94.1%
Lindane
0.002 mg/L ± 10%
0.0002 mg/L
94.5%
98.2%
Flow Rate=0.5 gpm (1.89 Lpm) Capacity=500 gallons (1893 L) or 6 months
Testing was performed under standard laboratory conditions, actual performance may vary
RC-EZ-4 Cartridges
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the
substances listed below. The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance
Influent Challenge
Concentration
Maximum
Permissible
Product Water
Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42
Chlorine
2.0 mg/L ± 10%
≥
50%
96.2%
97.0%
Chloramines
3.0 mg/L ± 10%
0.5 mg/L
97.6%
98.0%
Particulates
(0.5 to<1µm)-Class I
at least 10,000
particles/mL
≥
85%
99.9%
99.9%
Standard 53
MTBE
0.015 ± 20%
0.005 mg/L
69%
96.8%
96.9%
Cyst
Minimum 50,000/L
99.95%
99.95%
99.9%
Turbidity
11 mg/L ± 1 NTU
0.5 NTU
96.6%
98.0%
Lead (pH 6.5)
0.15 mg/L ± 10%
0.010 mg/L
99.3%
99.3%
Lead (pH 8.5)
0.15 mg/L ± 10%
0.010 mg/L
94.1%
99.3%
Mercury (pH 6.5)
0.006 mg/L ± 10%
0.002 mg/L
96.7%
96.7%
Mercury (pH 8.5)
0.006 mg/L ± 10%
0.002 mg/L
96.6%
96.6%
Chloroform (VOC surrogate
chemical)
0.300 mg/L ± 10%
0.015 mg/L
99.8%
99.8%
Flow Rate = 0.5 gpm (1.89 Lpm); Capacity = 500 gallons (1893 L) or 6 months
Testing was performed under standard laboratory conditions, actual performance may vary.
Test Conditions:
Flow Rate
= 0.5 gpm
Inlet Pressure
= 60 psi (4.1 bar)
pH
= 7.5 ± 1
Temperature
= 68° F ± 5° F (20° C ± 2.5° C)
Operating Requirements:
Pressure
= 30 - 100 psi (2.1 - 6.9 bar)
Temperature
= 40° - 100° F (4.4° -37.7° C)
Turbidity
= 5 NTU Max
WARNING:
Do not use with water that is microbiologically unsafe or
unknown quality without adequate disinfection before or after the system.
NOTE:
Substances reduced are not necessarily in your water. Filter must be
maintained according to manufacturer’s instructions, including replacement of
filter cartridges.