20
Performance
Data Sheet
Culligan
®
Sulfur-Cleer
™
Water Filter
Important Notice —
Read this data sheet and compare the capabilities of the unit to your actual
water treatment needs. Culligan recommends that you have your water supply tested to determine
these needs before purchasing a water treatment unit.
Culligan knows the more informed you are about your water treatment system, the more confident
you will be about its performance. It’s because of this more than seventy years of commitment to our
customers that Culligan is providing this Performance Data Sheet to its customers.
Manufacturer Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018
1-800-CULLIGAN or (847) 430-2800
www.culligan.com
Substance Reduction
Model
Substance USEPA SDWA*
MCL (MG/L)
Percent
Reduction
Average Influent
Concentration Level
Average Effluent
Concentration Level
Sulfur-Cleer
10” Fiberglass
Hydrogen
Sulfide
98.9%
8.2 mg/L
0.091 mg/L
0.3 mg/L
98.7%
10.4 mg/L
0.14 mg/L
Iron
Sulfur-
Cleer 10”
Quadrahull
Hydrogen
Sulfide
98.9%
8.2 mg/L
0.091 mg/L
0.3 mg/L
98.7%
10.4 mg/L
0.14 mg/L
Iron
* United States Environmental Protection Agency Safe Drinking Water Act
Testing Conditions
Capacity:
1,000 gallons)
Temperature: 63°F - 73°F
(17°C - 23°C)
Flow Rate:
5 gpm
pH:
8.0
Operating Conditions
Water Pressure Limits:
20 - 60 psi
Temperature Limits:
33 - 120°F
Electrical Characteristics: 120V/60 Hz 7 Watts continuous
Systems tested against WQA S-200 for the effective reduction of iron, and WQA Test Protocol 04-001 and NSF/
ANSI 42 for the efective reduction of hydrogen sulfide as verified and substantiated by test data.
This system has been tested according to NSF/ANSI 42 for the reduction of iron and hydrogen sulfide. The
concentration of iron and hydrogen sulfide in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42.
Testing was performed under laboratory conditions, actual results may vary.
Performance Indicator: If water flow decreases or a noticeable odor returns, the filter should be reconditioned. If
conditions do not improve, contact your local Culligan dealer. He can determine if your filter requires servicing.
Regeneration Frequency: Regeneration frequency will vary depending upon water conditions.
Refer to your Installation and Operation Instructions, Parts List and Printed Warrantees for more specific product
information. To avoid contamination from improper handling and installation, your system should only be installed
and serviced by your Culligan Man. Performance may vary based on local water conditions. The substances
reduced by this product are not necessarily in your water.
Buyer Signature
Date
Seller Signature
Date
Pressure:
20-60 psi
(1.4 - 4.2 Kgf/cm
2
)
Acidity:
Non-Corrosive
Rated Pressure Drop @ 3 gpm: 5 psi