9
If any of the days were set to “yes”, the display will show
“SETDAY” followed by “SUN”. This selects the current day of the
week. The “+” or “-“ key toggles through the days of the week
and pressing the “STATUS” key saves the setting and advances to
the next programming step.
If ALL of the days were set to “no”, then “days 03” will appear
as shown above and the regeneration interval will be set in
number of days. Pressing the “STATUS” key saves the setting and
advances to the next programming step.
• Cycle 1 Time (Backwash) -
This setting is used to program
the cycle 1 time that is usually backwash. The time of the cycle is
kept in minutes. The display will show “bw” in the left most digits
and the cycle time in the right most digits. Adjust the value with
the “+” or “-“ keys. Use the default value of 10 minutes, or the
appropriate time to allow the drain flow to be clear.
Pressing the “Status” key will save the setting and move to the next programming step.
• Cycle 2 Time (Brine Draw/Slow Rinse) -
This setting is
used to set the time in minutes for cycle 2. This cycle is usually
brine draw / slow rinse for softeners and a settling time for filters.
The display will show “br” in the left most digits and the cycle time
in the right most digits. Adjust the value with the “+” or “-“ keys.
Adjust this cycle to 90 minutes if educting diluted bleach. Adjust
this cycle to 2 minutes if not educting diluted bleach.
Pressing the “Status” key will save the setting and move to the next programming step.
• Cycle 3 Time (Fast Rinse/Refill) -
This setting is used to set
the time in minutes for cycle 3. This cycle is usually fast rinse for
softeners and filters. The display will show “Fr” followed by the
cycle time for this step. Adjust the value with the “+” or “-“ keys.
Adjust the cycle time to 6 minutes.
Pressing the “Status” key will save the setting and move to the
next programming step.
Programming
(cont.)
NOTE:
1. If any day of the week is set to “yes”, the regeneration interval in number of days (“Days
03”) will no longer appear when going through the programming menu at a later time.
To go back from specific day of week regeneration to interval in number of days, choose
“NO” at “dAYoWK”.
2. If a DIPswitch is changed anytime after the control has been programmed to regenerate
on any specific day, all settings will revert back to default; specific days to regenerate and
current day will have to be reprogrammed.
REGEN