- 18 -
DOOR SWITCH ADJUSTMENT
You may also wish to adjust the door switch. The door switch is located behind
the combustion compartment cover, on the right side. The door switch is activated by a
cam, which is mounted to the door's hinge pin with a setscrew.
1.
Open the doors fully.
2.
Remove the lower cover by loosening the four screws located inside the door opening.
3.
Position the doors so they are nearly closed but not latched.
4.
To adjust the cam loosen the setscrew and rotate the cam until you hear the switch click.
5.
Tighten the setscrew in the cam. Test the door to make certain the switch will make
contact with the doors closed.
6.
Torque setscrew to 60 in-lbs.
7.
Replace the combustion cover.
WARNING: The door turnbuckles and door switch are located in a heated in a heated
zone. Care should be taken to avoid burns.
VENTILATION SYSTEM
It is important that the ventilation system be inspected and/or maintained by Qualified
Personnel at least once each year.
This inspection/maintenance should consist of, but not be limited to:
1.
Inspection for blockages or build up which might interfere with the venting the venting
of
the oven.
2.
Repair of such blockages.
3.
Proper installation of the draft hood or flue guard.
4.
Inspection of the venting canopy, its drive motors and belts, etc.
5.
Proper preventive maintenance can reduce your chances of costly repairs.