10
In
more
detail...
GH60GGAR
Built-in Gas Hob
GB
IE
Operation
Operation
Use of the burners
Caution
•
If there is no electric current you can light the burners with piezo
electric spark gas ignitor.
•
The burners can only be lit with safety thermocouples when the
knob is on
MAXIMUM
.
On the right bottom side of each knob on the control panel there is a diagram to
indicate the burner to which the knob refers to. The burners can be switched on in
several ways, according to the type of appliance and its individual features.
Manual “ON” switch (this is always possible even if the
electric current is off):
•
Turn the knob corresponding to the selected burner
in a counter-clockwise direction so that the knob is
at MAXIMUM (this corresponds to a large flame).
•
Use a piezo electric spark gas ignitor.
Automatic electric “ON” switch for burners with safety
device (thermocouples):
•
Turn the knob corresponding to the selected burner
in a counter-clockwise direction so that the knob is
at MAXIMUM.
•
Once the burner is lit, keep the knob pressed in for
about 10 seconds in order to allow the flame to heat
up the thermocouple. If the burner goes out when
the knob is let go, repeat the operation.