OPERATION
17
•Beware of the pinch point between the burner arm (horizontal rod) and the vertical pole,
when lowering and raising the head (Fig.1).
•Certain materials or items, when stored under the heater, will be subjected to radiant
heat and could be seriously damaged.
•Inspect the visible portion of the hose before each use of the appliance. The hose inside
cylinder pole housing should be checked annually and a leak test should be performed
when re-assembled.
•Children and adults should be alerted to the hazards of high surface temperatures and
should stay away to avoid burns or clothing ignition.
•Young children should be carefully supervised when they are in the area of the heater.
•Clothing or other flammable materials should not be hung from the heater, or placed on or near the heater.
•Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater.
•Installation and repair should be done by a qualified service person. The heater should be inspected before use
and at least annually by a qualified service person.
•More frequent cleaning may be required as necessary. It is imperative that the control compartment, burners
and circulating air passageways of the heater be kept clean.
•Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and
liquids.
•Do not obstruct the flow of combustion and ventilation air.
•Keep the ventilation openings of the cylinder enclosure free and clear from debris.
•The propane-gas supply cylinder to be used must be: a. Constructed and marked in
accordance with the specifications for propane-gas cylinders of the U.S. Department
of Transportation (DOT); or the Standard for cylinders, Spheres and Tubes for
Transportation of Dangerous Goods and Commission, CAN/CSA-B339, as
applicable; b. Provided with a listed overfilling prevention device; and c. Provided
with a cylinder connection device compatible with the connection for the appliance. d. 20 lb (9 kg) cylinder.
LPG capacity 4.7 gallons (17.8 litres). Cylinder Dimensions: Height 17.75 in. (451 mm) and width 12.25 in.
(311 mm). The propane gas cylinder used must include a collar to protect the cylinder valve.
•A cylinder must be stored outdoors in a well-ventilated area out of reach of children. A disconnected cylinder
must have dust caps tightly installed and must not be stored in a building, garage or any enclosed area. The
pressure regulator and hose supplied must be used and any replacement pressure regulator or hose must be
those as specified by the manufacturer.
•Do not store spare propane-gas cylinder under or near this appliance.
•Never fill the cylinder beyond 80% full; and for appliances designed to use a CGA No. 791 connection, place
the dust cap on the cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on
the cylinder valve that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of
propane.
POSITIONING INSTRUCTIONS
•This appliance is for OUTDOOR USE ONLY and should be placed in a well
ventilated area.
•A well ventilated area must have a minimum of 30% of its surface area open.
(Surface area is defined as the total surface of the walls.)
•The sides of the appliance should NEVER be closer than 40 in. (1 m) from any
combustible surface.
40 in. (1M)
40 in. (1M)
Fig. 1
12.2 in.
18 in.
8 in.
12.3 in.