Remove the 3 screws shown (left) and set aside for reassembly.

Install the LiDAR onto the RVC (right) using the four M3 screws provided 

with the LiDAR. Hardware: 4X – HW952

Reinstall the intake/blower portion of the assembly using the three screws 

that were previously removed (left). Install the mounting plate to SF380 using 

the five screws that were bagged and tagged with SF385 (right).

6

SF973-INST

Содержание Solid FX

Страница 1: ...er SF973 INST Description SolidFX Mud Master Kit Instruction Sheet Signature CHKR ____________________ Signature ENGR ___________________ Signature MFG ____________________ 1 SF973 INST Tony Winiewicz...

Страница 2: ...l hoses PTC fittings and NPT fittings is recommended 3 Applying DeoxIT to electrical connections is recommended 4 Dust caps should be applied to all receptacles that are not in use 5 When plugging in...

Страница 3: ...cover and cut the zip tie to remove the TM356 cable Reinstall the rear cover and apply dust caps and dummy plugs to the TM356 cable Hardware 160553 EC431 EC3465 MS398 The cables shown will not be need...

Страница 4: ...rom the Mud Master Chassis The electric lift will not be needed in this configuration Retain hardware for future installation Install SF750 onto the Mud Master chassis as shown Mounting hardware 4X 10...

Страница 5: ...ight Array SF380 Installation of the LiDAR SF362 will also be covered Remove the two screws shown RVC Repeat for the 2 screws on the other side Set these 4 screws aside for reassembly RVC subassembly...

Страница 6: ...ht using the four M3 screws provided with the LiDAR Hardware 4X HW952 Reinstall the intake blower portion of the assembly using the three screws that were previously removed left Install the mounting...

Страница 7: ...ow Reinstall the RVC blower subassembly to the mounting plate using the 4 screws that were previously removed The light array will now be mounted to the top half of the manual lift SF749 This will all...

Страница 8: ...he SF380 with SF385 mounted and SF749 Align SF749 as shown Note It may be necessary to loosen the mounting tabs on SF380 Fix the SF749 to the light array using the four button head screws provided wit...

Страница 9: ...ant install the set screw provided with SF239 as shown left Rotate the valve on SF252 counterclockwise until it is all the way Closed Screw the SF225 pressure tank into SF252 Note DO NOT open valve un...

Страница 10: ...Note orientation of SF791 Next SF251 will be mounted to SF791 Mount SF251 to SF791 Mounting Hardware 2X 101024 2X 101736 10 SF973 INST...

Страница 11: ...housing Heat up the tubing to shrink it in place Repeat for the other HW4077 hose clamp Note orientation of assembly Thread the two hose clamps and align them in the back two cutouts of the SF791 mou...

Страница 12: ...en down hose clamps to secure the assembly NOTE SF250 should be securing the valve portion of the regulator tank assembly NOT the neck of the pressure tank Install SF250 Mounting Hardware 2X 104044 Or...

Страница 13: ...fitting that corresponds with the black tubing on the SF382 Repeat for the blue and red tubing Make sure all tubing is properly mated with the PTC fittings Note Don t kink pinch the tubing or cable w...

Страница 14: ...104 1X 101001 Route the black tubing around the back side of the regulator Cut the black tubing to an appropriate length for it be plugged into the 90 PTC fitting on the regulator Insert the end of th...

Страница 15: ...te the red tubing through SF791 as shown Route the red tubing through the two tube clamps on the side of SF380 Remove the set screw from the hole shown Route the tube through a hose clamp and secure H...

Страница 16: ...fitting shown Make sure the tubing is properly mated Plug the LiDAR cable into the 12 pin receptacle shown Remove the dust cap from the RVC and plug in the 4 pin end of the SF603 cable into the camera...

Страница 17: ...e shown Remove the set screws from the holes shown below Route and secure the cable with hose clamps as shown Hardware 2X 121106 2X 101001 Plug in one end of the EC1154 cable into the 5 pin receptacle...

Страница 18: ...View of Routing for Pneumatic Tubing View of Routing for Pneumatic Tubing 18 SF973 INST...

Страница 19: ...guard SF381 1 Retain for sonar guard reassembly Repeat the last step for the screws on the other side Place sonar into cradle and align pin to socket as shown below Note The sonar should not be able t...

Страница 20: ...e the threaded jacket forward and screw into the sonar Route the loose end of the sonar cable through the clearance hole in the chassis left Mount the sonar guard as shown using the forward 4 mounting...

Страница 21: ...Reference pictures for mounted sonar position Secure the sonar cable as shown Hardware 2X 121104 2X 101001 21 SF973 INST...

Страница 22: ...maining length of sonar cable as shown Plug the 12 pin end of the sonar cable into the 12 pin receptacle shown Note The sonar cable should be routed such that manual lift operation does not damage the...

Страница 23: ...l the mounting block slide into place Loosen the four screws on the top clamp of SF380 slide the camera into the channel and tighten the four screws to secure camera Plug the SF349 1 cable into the 4...

Страница 24: ...Plug the 8 pin end of the SF393 cable into the camera Apply dust caps that were provided with SF379 to all unused receptacles 24 SF973 INST...

Страница 25: ...Views of Complete Assembly 25 SF973 INST...

Страница 26: ...Configuration Unplug the SF349 1 cable from the electronics box Unplug the blue tubing from the PTC fitting on the front of the DUC Place PTC cap on the end of the blue tubing Hardware HW4435 26 SF973...

Страница 27: ...ir positions for OZ II cable routing Route the SF618 cable as shown Plug the 8 pin end of the cable into the 8 pin receptacle on the electronics box Plug the 4 pin end of the cable into the RVC Place...

Страница 28: ...Views of Complete Assembly 28 SF973 INST...

Отзывы: