Introduction 

2.1.

 

Overview 

The airCUE-8X10 and airCUE-6X10 and are superior touch panels cater to the full integration of lifestyle as 
well as work style. It combines functionality such as multimedia integration, lighting automation, security 
monitoring, entertainment integration, and meeting & presentation control. Unleashed by Wi-Fi this classical 
beauty gives professional presenters and homeowners the wireless freedom that they love. From living room 
to garden, boardroom to break-room, anywhere there is wireless LAN, both models put them in control and 
keep them connected to the world. The long battery life and quick charger keep them wireless with fewer pit 
stops. The active matrix touch screen display offers resolution 800 x 600 pixels (airCUE-8X10) or 640 x 480 
pixels (airCUE-6X10) and it produces stunning high color images. Innovative design features like 256 MB of 
standard data storage provides a level of capability not available with other similar touch panels. Wired 
Ethernet connection provides easy network integration. Fully compatible with CUE controllers, this touch 
panel provides the ultimate one-touch solution for meeting rooms, conference rooms, boardrooms and high-
tech homes. Flexible tabletop or wall installation can be done using four types of accessories. 

2.2.

 

airCUE-8X10 Models & Available Accessories 

 

Model 

Stainless steel 

enclosure 

Wooden enclosure, 

white birch

 

Wooden enclosure, 

oak

 

Wooden enclosure, 

mahogany 

Plastic enclosure, 

stardust black 

Plastic enclosure, 

abrasive white 

airCUE-8X10 

CS0300-001 CS0300-002 CS0300-003 CS0300-004 CS0300-005 

airCUE-8X10 Tabletop Docking Station 

CS0301-001 CS0301-002 CS0301-003 CS0301-004 CS0301-005 

airCUE-8X10 

Wall 

Docking 

Station 

CS0302-001 CS0302-002 CS0302-003 CS0302-004 CS0302-005 

airCUE-8X10 

Tabletop 

Stand 

CS0303-001 

- - - - - 

airCUE-8X10 

Wall 

Mounting 

Adapter 

CS0304-001 

- - - - - 

 

2.3.

 

airCUE-6X10 Models & Available Accessories 

 

Model 

Stainless steel 

enclosure 

Wooden enclosure, 

white birch

 

Wooden enclosure, 

oak

 

Wooden enclosure, 

mahogany 

Plastic enclosure, 

stardust black 

Plastic enclosure, 

abrasive white 

airCUE-6X10 

CS0305-001 CS0305-002 CS0305-003 CS0305-004 CS0305-005 

airCUE-6X10 Tabletop Docking Station 

CS0306-001 CS0306-002 CS0306-003 CS0306-004 CS0306-005 

airCUE-6X10 

Wall 

Docking 

Station 

CS0307-001 CS0307-002 CS0307-003 CS0307-004 CS0307-005 

airCUE-6X10 

Tabletop 

Stand 

CS0308-001 

- - - - - 

airCUE-6X10 

Wall 

Mounting 

Adapter 

CS0309-001 

- - - - - 

Содержание AIRCUE-6X10

Страница 1: ...CUE a s K Nouzovu 6 143 00 Praha 4 Czech Republic fax 420 241 432 446 www cuesystem com mail info cuesystem com phone 420 241 091 240 User Manual airCUE 8X10 airCUE 6X10 Version 01...

Страница 2: ...User Manual airCUE 8X10 airCUE 6X10 UM030_01 1 6 2007 Copyright CUE a s Praha Czech Republic 1990 2007 All rights reserved Specifications are subject to change without prior notice...

Страница 3: ...Specifications 7 5 Physical Description 8 5 1 Front Panel 8 5 2 Top Panel 10 5 3 Rear Panel 11 5 4 Bottom Panel 12 6 Setup and Using 13 6 1 Switch On Off 13 6 2 Charging 13 6 3 PC Connection 14 6 4 Ac...

Страница 4: ...controllers this touch panel provides the ultimate one touch solution for meeting rooms conference rooms boardrooms and high tech homes Flexible tabletop or wall installation can be done using four t...

Страница 5: ...red Ethernet connection Power over Ethernet PoE IEEE 802 3af compatible Battery charging from Power over Ethernet Four programmable buttons Web server and Admin Web pages for setup and diagnostics Bui...

Страница 6: ...ith 1 Touch panel airCUE 8X10 or airCUE 8X10 2 Stylus 3 Ethernet cable straight through 4 Ethernet cable crossed over 5 CUEadapter 30W incl power cable 6 Cleaning tissue 7 CE Declaration of Conformity...

Страница 7: ...external power supply Red indicates charging of battery pack Wi Fi yellow green indicates wireless network Memory 128 MB RAM CompactFlash Card min 256 MB upgradeable Software technologies Admin Web X...

Страница 8: ...arging Indicator Off The device is off Blue On The device is switched on Green On External power supply is connected Red On Battery pack is being charged Wi Fi Indicator Off No Wi Fi connection Green...

Страница 9: ...e It is not supported by current firmware version Programmable Buttons The airCUE is equipped with 4 programmable buttons numbered from left Default button functions are as follows Button 1 On Screen...

Страница 10: ...the On Screen Display Use of other pointers could damage our screen When stylus is not used you can place it in the storage slot located on the top right corner of airCUE Power Button The button Power...

Страница 11: ...cable For the direct PC connection it is necessary to use cross over cable for the connection to Ethernet switch straight through cable The length of the Ethernet cable connecting touch panel to the n...

Страница 12: ...When pressed shortly 2 seconds the reset of the unit is performed followed by operating system boot taking approx 13 seconds 2 When pressed longer for approx 5 seconds the factory default function is...

Страница 13: ...ower supply unit to the power supply connector located on the bottom panel of airCUE and attach power cable to a power outlet The green indicator will light when external power supply is connected and...

Страница 14: ...Network Interface Card 2 NIC 2 Touch panel RJ45 Male Connector Name NIC 1 Color NIC 2 Name TX BI_DA 1 White Orange 3 RX BI_DB TX BI_DA 2 Orange 6 RX BI_DB RX BI_DB 3 White Green 1 TX BI_DA BI_DC 4 Bl...

Страница 15: ...ch the other end of the RJ 45 Ethernet cable to your computer Windows XP Local Area Connection Settings Steps are 1 Start Windows XP 2 Click Start then click Control Panel choose the option to switch...

Страница 16: ...our PC and type in the touch panel factory default IP address 192 168 1 128 The Admin login web page will be displayed The password is set to default 6 5 Wireless Communication Settings Please use Adm...

Страница 17: ...L It s necessary to have appropriated touch panel properly inserted and configured 5 Right click on airCUE xxx Layout and select Download layout Using Admin Web Steps are 1 Connect touch panel to your...

Страница 18: ...n Display Screen Backlight Saver will switch off automatically the display backlight off to conserve battery power and fluorescent tubes lifetime Power Down mode will be reached automatically if enabl...

Страница 19: ...rector program written for your specific application For control systems with more than one unit a unique IP address must be given to each CUE device For setting please select appropriate field and us...

Страница 20: ...stem com Page 20 of 28 Calibration Use this page for calibration We recommend use stylus Battery This page shows current battery status and it s charging modes The type of external power source is ind...

Страница 21: ...cotton 2 Spray bottle of cleaning solution without alcohol window cleaner 3 Stainless steel parts should be cleaned using a special cleaning solution for example 3M Stainless Steel Cleaner Polish SS91...

Страница 22: ...mpty Internet Clock Empty Date and Time Time zone GMT 0 Date and time Unchanged IP Connection Host name Empty IP address 192 168 1 128 Subnet mask 255 255 255 0 Default gateway Empty DNS Empty Applica...

Страница 23: ...ou agree that any copies of the Software will contain the same proprietary notices which appear on and in the Software Prohibited Uses Without obtaining prior written permission from CUE You may not a...

Страница 24: ...and after warranty services are made at CUE premises It is strictly prohibited to repair CUE products or to change any accessory parts except those parts with limited service life CUE is not liable f...

Страница 25: ...9 V ipCUE gamma CS0253 touchCUE MV 99 CS0235 W V CS0235 O V CS0235 M V ipCUE Rack Mounting Kit CS0251 MR touchCUE S CS0247 IR Adapter i CS0256 touchCUE S b CS0241 irCUE 99 CS0149 WA CS0149 OA CS0149 M...

Страница 26: ...o frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occ...

Страница 27: ...User Manual airCUE 8X10 airCUE 6X10 www cuesystem com Page 27 of 28 Notes...

Страница 28: ...User Manual airCUE 8X10 airCUE 6X10 www cuesystem com Page 28 of 28 Notes...

Отзывы: