background image

 
 
 

 

Part:  CubeSense V3 
Doc:   User Manual 
Ver:  

1.11 

Page:  11 

5 = SRAM overcurrent 

Detection 
result 

Unsigned 
8-bit 

0 = start-up 
1 = no detection scheduled 
2 = detection pending 
3 = Nadir error 

 too many 

detected edges 
4 = Nadir error 

 not enough 

detected edges 
5 = Nadir error 

 Bad fit 

6 = Sun error 

 Sun not found 

7 = Successful detection 

The  first  step  after  reading  this  TLM  is  to  check  the  detection  and  capture-results.  The 
description of each result is detailed in the table above. 

Only  when the  capture result is 

Successful

ly  captured”  and  the  detection  result  is  “Successful  detection”  should  the 

result in bytes 0-3 be used as valid detection results. 

 

 

 

Содержание Sense V3

Страница 1: ...CubeSense V3 An integrated sun and nadir sensor module User Manual...

Страница 2: ...Support Program GSP 4 2 4 Hardware setup 6 3 Usage 8 3 1 Identification 8 3 2 Managing memory contents 9 3 3 Doing detection 10 3 4 Interpreting detection result 12 3 5 Capturing and downloading image...

Страница 3: ...eyn Signature List of Acronyms Abbreviations CMOS Complementary metal oxide semiconductor ADCS Attitude and Determination Control System FPGA Field Programmable Gate Array I2 C Inter Integrated Circui...

Страница 4: ...be implemented The unit must never be handled without proper grounding It is recommended that the unit be handled in a clean environment A clean room of ISO class 8 or better or an appropriate laminar...

Страница 5: ...re required before the user can get started with the CubeSense Multi meter or oscilloscope Ground Support Program see Section 2 3 Computer with an open USB port running Windows 7 or later 2 3 Ground S...

Страница 6: ...assigned to the cable by browsing to Device Manager and noting the number shown under Ports COM LPT for USB Serial Port COM x The number given by x will be used to connect to CubeSense The connection...

Страница 7: ...tec TFC 104 01 F D The 3V3 power is located at pin 1 as shown in Table 1 Table 1 Pinout of CubeSense Connector Pin Name Description 1 3 3V Input voltage of 3 3V 2 SDA1 SDA line for I2C communication 3...

Страница 8: ...ccessful check the following Verify that the CubeSense is plugged into the support PCB Verify that the UART connection cables are plugged in correctly In case of continuous connection issues probe pin...

Страница 9: ...mware version major Unsigned 8 bit 3 1 Firmware version minor Unsigned 8 bit 4 2 Runtime seconds Unsigned 16 bit Number of seconds since processor start up 6 2 Runtime milliseconds Unsigned 16 bit Num...

Страница 10: ...This is illustrated in Figure 2 2048 Kilobytes Top 1 MB Used for Image capture from camera Sun detection Nadir detection Bot 1 MB Used for Image capture from camera SRAM Figure 2 SRAM layout Each 1 MB...

Страница 11: ...t any parameters 2 Request TLM 22 for the last detection result and automatically trigger new capture and detection When requesting the latest detection result through these TLMs a new detection is au...

Страница 12: ...not enough detected edges 5 Nadir error Bad fit 6 Sun error Sun not found 7 Successful detection The first step after reading this TLM is to check the detection and capture results The description of...

Страница 13: ...following formula 100 2 100 2 4 Then the direction vector is sin cos sin sin cos In finding the and detection values the sensor makes use of a calibrated bore sight location on the imaging sensor Thi...

Страница 14: ...ccessfully captured Byte 4 Capture Result in this TLM can be used to read the status of the capture Once the required image is captured it will be stored as long as the CubeSense module is powered or...

Страница 15: ...16 bit Number of current frame loaded into download buffer 2 1 checksum Unsigned 8 bit XOR checksum of frame loaded into download buffer Once the frame number is set to 0 the image frame can be reque...

Страница 16: ...me number channel is equal to the appropriate image frame These steps can be repeated until all frames have been downloaded The data for an image with dimensions X by X can be packed into a bitmap in...

Страница 17: ...Part CubeSense V3 Doc User Manual Ver 1 11 Page 16 Figure 5 Flow diagram for typical use...

Страница 18: ...vant celestial body is identified The threshold is set to a default value optimized for robust measurements If the user wishes to change the threshold values telecommand 40 can be used It is however r...

Страница 19: ...mber of detected edge points The Min and Max Radius parameters telecommand 15 can be used to specify the valid range of the circle radius This will depend on the height of the satellite in its orbit T...

Страница 20: ...rrect telemetry and telecommands to perform masking Figure 7 Object masking When the CubeSense is used with the within a CubeADCS running CubeACP the image will first need to be transformed before rea...

Страница 21: ...Part CubeSense V3 Doc User Manual Ver 1 11 Page 20 Figure 8 ACP image transformation...

Страница 22: ...GJVV ALL 02 08 2016 Template and formatting update 1 3 DS ALL 05 08 2016 Updated for new software 1 4 1 6 DS ALL 19 01 2017 Various corrections 1 7 DS ALL 08 02 2017 Shifted various info to the ICD 1...

Отзывы: