CTI Janus Programmable Automation Controller IOG
Controller Run Mode Startup Errors
Error
Code
Description
Priority
Operation
Error Recovery
080
No Application Program
Found
8
Controller stopped.
Download program from Janus
Workbench.
085
Specified Startup Mode
Unavailable
(Application cannot start as
configured due to abnormal
shutdown, unsupported
program version, or PLC
installed in I/O module slot
with application that includes
Local I/O)
9
Controller stopped.
Two possible reasons:
(1) PLC could not complete an
orderly shutdown due to loss of
power. Connect Workbench to start
application or press
Clear Exception
button
to trigger “Cold Start”.
(2) PLC inserted into I/O module
slot 1-16 and application includes a
Local I/O config. Modify application
to remove LIO config or move PLC
to Slot 0.
110
Local I/O driver failed to start 11
Controller stopped.
Reset Controller.
Contact CTI.
120
Remote I/O driver failed to
start
11
Controller stopped.
Reset Controller
Contact CTI.
140
Profibus I/O driver failed to
start
11
Controller stopped.
Reset Controller.
Contact CTI.
150
CTI Data Cache Client driver
failed to start
12
Controller stopped.
Reset Controller.
Contact CTI.
160
CAMP Client driver failed to
start
12
Controller stopped.
Reset Controller.
Contact CTI.
165
CAMP Server driver failed to
start
12
Controller stopped.
Reset Controller
Contact CTI.
170
MODBUS Client driver failed
to start
12
Controller stopped.
Reset Controller.
Contact CTI.
175
MODBUS Server driver failed
to start
12
Controller stopped.
Reset Controller.
Contact CTI.
180
Ethernet/IP Scanner driver
failed to start
12
Controller stopped.
Reset Controller.
Contact CTI.
185
Ethernet/IP Adapter driver
failed to start
12
Controller stopped.
Reset Controller
Contact CTI.
190
Ethernet/IP Tag Client driver
failed to start
12
Controller stopped.
Reset Controller
Contact CTI.
195
Ethernet/IP Tag Server failed
to start
12
Controller stopped.
Reset Controller.
Contact CTI.
210
MQTT Client driver failed to
start
12
Controller stopped.
Reset Controller.
Contact CTI.
220
HTML5 Data Server driver
failed to start
12
Controller stopped.
Reset Controller.
Contact CTI.