I-DSL64 USER’S MANUAL
24
-- CSU LOOP --
REMOTE RTN OK !!
4.4.3.2
NT Mode
Step 1
Enter ”DEVICE DIAGNOSTIC” screen, then press (Enter)
DEVICE
DIAGNOSTIC
Step 2
Use
(
Left arrow) or
(
Right arrow) to choose “CSU
LOOPBACK”, then press (Enter) .
CSU
LOOPBACK
Step 3
Use
(
Left arrow) or
(
Right arrow) to choose “AUTO” or
“OFF”, then press (Enter) .
* CSU LOOP *
AUTO OFF
4.5
DSU Loopback
When you initiate the DSU loopback test, the transmitting unit will send a loopback
message, specified by ITU-T V.54, to the receiving unit. Either the local or remote site
can initiate the test. When the receiving unit receives a valid loopback message from
the transmitting unit, it will send back an acknowledgement message and execute a
DSU loopback. This tests the B1, B2 or B1+B2 channel, as well as the condition of the
DSL.
When the DSU loopback is activated, the Loop LED will be turned on. It will be
turned off when a valid release pattern is received.