Installation
Single pipe system
For pure single-pipe operation the bypass stopper
must be unscrewed out of the return line opening and
the return line opening must be sealed with a gasket
and metal stopper.
For conversion to single pipe system, we recommend
to use a fuel oil filter with return feed. For this, the
pump remains in two-pipe operation. Install flow and
return burner pipes at the filter. Open the oil tap at the
filter. Start the installation.
Oil pump
On the
version -AE
(startup relief) or
-Z
(two-stage)
the oil burner starts up with a low pump pressure and
switches to the higher pump pressure, i.e. full output,
via the solenoid valve in the pump.
-AE
Differential pressure max. 3 bar. Ex-works setting
10 and 13 bar.
-Z
Ex-works setting 10 and 20 bar
The pump pressure can be set for the relevant output
(see Table of settings Pages 13-14).
To do so:
•Remove the sealing plug.
•Screw in the pressure gauge and adjust the pump
pressure by means of the control valve in accor
dance with the table of settings.
Key to Suntec pump:
1 = Feed line
2 = Return line
3 = Pressure pipe connection
4 = Pressure measuring connection
5 = Vacuum measuring connection
6 = Pressure adjustment 1st stage
7 = Pressure adjustment 2nd stage
8 = Solenoid valve 1st stage
9 = Solenoid valve 2nd stage
Oil
throughput
[kg/h]
Di
[mm]
H [m]
4
3
2
1
0
-1
-2
-3
-4
bis 2,5
4
77
68
58
49
40
31
22
13
-
6
100
100
100
100
100
100
87
64
18
8
100
100
100
100
100
100
100
100
56
2,5-5,0
4
39
34
29
25
20
16
11
6
-
6
100
100
100
100
100
79
56
32
9
8
100
100
100
100
100
100
100
65
28
5,0-10,0
4
19
17
15
12
10
8
-
-
-
6
98
86
74
63
51
39
28
16
4
8
100
100
100
100
100
100
88
51
14
10,0-23,0
6
42
37
32
27
22
17
12
7
-
8
100
100
100
85
69
54
38
22
6
Suntec:
2-stage