68
CTC EcoZenith i550 Pro
For the property owner
9.5.3 Define
System
The menus are used to specify to the EcoZenith the
components and subsystems which make up the
heating system.
9.5.3.1
Def heating circuit 1
Room sensor 1 (B11)
No (Yes/No)
Specify whether the room sensor (B11) should be
connected to the system.
Wired or wireless
Wired/Wireless
Select whether the room sensor for heating system 1 is
permanently connected (wired) or wireless.
9.5.3.2 Def heating circuit 2 (3)
If heating circuit 3 has been defined, there is no cooling.
Heating circuit 2 (Y2, G2)
No (Yes/No)
Select whether or not further heating systems should be
connected.
Room sensor 2 (B12)
No (Yes/No)
Select whether the room sensor for heating system 2 (3
and 4) should be connected to the system. Displayed if
the heating circuit in question has been defined.
Wire or wireless Wireless (Wire/Wireless)
Select whether the room sensor for the respective
heating system 1 is permanently connected (wired) or
wireless.
9.5.3.3 Def. heat pump
Heat pump A1-A3
Off (On/Off
Select the heat pumps to connect to the system.
Flow/level switch
None (None/NC/NO)
Select the type of level switch installed in the system.
“NC” and “NO” stand for Normally Closed and Normally
Open, respectively.
9.5.3.4 Def. DHW tank
DHW circulation (G40)
No (Yes/No)
Specify whether the circulation pump (G40) is connected
to the hot water system.
External DHW tank (G41, B43)
No (Yes/No)
Specify whether the circulation pump (G41) and sensor
(B43) are connected to the hot water system.
Define System
Radiator system1
Radiator system2
Radiator system 3
Heat pump
DHW tank
External buffer
No
Solar Panel
Electric heaters
Wood boiler
No
Ext. boiler
No
Pool (G50, G51, B50)
No
Cooling (B3, B13, Y3, G3)
No
SMS
Input voltage
3x400V
Define Heating circuit 2
Radiator system 2 (Y2, G2)
Yes
Room sensor 2 (B12)
Yes
Type Wireless
Def. Heat pump
Heat pump A1
Off
Heat pump A2
Off
Heat pump A3
Off
Flow /level switch
None
Def. DHW tank
DHW circulation (G40)
No
DHW extra Buffer (B43, G41)
No
Содержание EcoZenith i550 Pro
Страница 1: ...162 105 20 1 2013 06 13 Installation and Maintenance Manual CTC EcoZenith i550 Pro...
Страница 95: ...97 CTC EcoZenith i550 Pro For the installer...
Страница 97: ...99 CTC EcoZenith i550 Pro For the installer 6725 7 1 6 1 287 322 7 36 1 7 5 1 1 D E...
Страница 120: ...122 CTC EcoZenith i550 Pro For the installer 20 Wiring diagram main card 3x400V...
Страница 121: ...123 CTC EcoZenith i550 Pro For the installer...
Страница 122: ...124 CTC EcoZenith i550 Pro For the installer 21 Wiring diagram main card 1x230V...
Страница 123: ...125 CTC EcoZenith i550 Pro For the installer...
Страница 124: ...126 CTC EcoZenith i550 Pro For the installer 22 Wiring diagram for expansion card...