60
CTC EcoZenith i550 Pro
For the property owner
9.5.2.5 Lower
tank
In the “lower tank” menu you make settings which affect
the operation of the lower part of the tank.
Tank max. °C
55 (20 to 70)
This menu is used to set the highest temperature
required for the lower tank.
Tank min. °C
25 (20 to 60)
This menu is used to set the lowest temperature
required for the lower tank.
Diff. tank and prim. flow °C
0 (0 to 15)
This menu is used to set the difference between the
temperature in the tank and the outgoing primary flow
temperature to the heating system, if required.
Start/Stop diff. tank °C
5 (3 to 10)
The hysteresis between the heat pump’s start and stop
conditions in charging the lower tank.
Timer setpoint
50 (20 to 60)
This menu is used to specify the setpoint that is active
during the period of time set by the timer.
Timer lower tank
See the chapter “Timer lower tank” below.
9.5.2.6 Timer lower tank
This menu is used to schedule the weekday periods
you require the lower tank to be heated. This schedule
is repeated every week. The illustration shows factory
settings, which can be modified.
Run time DHW circ.
4 (1 to 90)
The operating time the domestic hot water circulation
should take place during each period. Applies if DHW
circulation has been defined in the
Installer/Defined
system/DHW tank menu.
Cyclic time DHW circ.
15 (5 to 90)
The cyclic time for domestic hot water circulation. DHW
circulation must have been defined in the
Installer/
Defined system/DHW tank menu.
Diff start ext DHW buffer
5 (3...15)
This menu is used to select the temperature difference
at which the charging of the external DHW tank is
required to start. The difference is specified against the
setpoint that is set in the
Stop temp. HP °C menu.
Timer DHW circulation
This menu displays the scheduled weekday periods
when the DHW circulation pump is to run. This schedule
is repeated every week.
The circulation pump for hot water is set in the above menu to
run on Mondays between 6 am and 9 am and between 9 pm
and 11 pm.
06-09
00-00
06-09
00-00
06-09
00-00
06-09
00-00
06-09
00-00
03-09
00-00
06-09
00-00
Timer DHW circulation
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Lower tank
Tank max. °C
55
Tank min. °C
25
Diff. tank vs primary °C
0
Start/stop diff tank °C
5
Timer setpoint
50
Timer lower tank
06-07 00-00 00-00
06-07 00-00 00-00
06-07 00-00 00-00
06-07 00-00 00-00
06-07 00-00 00-00
07-08 00-00 00-00
07-08 00-00 00-00
Timer lower tank
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Weekly program
Off/Setpoint
Содержание EcoZenith i550 Pro
Страница 1: ...162 105 20 1 2013 06 13 Installation and Maintenance Manual CTC EcoZenith i550 Pro...
Страница 95: ...97 CTC EcoZenith i550 Pro For the installer...
Страница 97: ...99 CTC EcoZenith i550 Pro For the installer 6725 7 1 6 1 287 322 7 36 1 7 5 1 1 D E...
Страница 120: ...122 CTC EcoZenith i550 Pro For the installer 20 Wiring diagram main card 3x400V...
Страница 121: ...123 CTC EcoZenith i550 Pro For the installer...
Страница 122: ...124 CTC EcoZenith i550 Pro For the installer 21 Wiring diagram main card 1x230V...
Страница 123: ...125 CTC EcoZenith i550 Pro For the installer...
Страница 124: ...126 CTC EcoZenith i550 Pro For the installer 22 Wiring diagram for expansion card...