13
CTC EcoZenith C 530 l 510
For the installation technician
Left rear insulation
Pockets in the front insulation
Right rear insulation
The illustration shows
EcoZenith
I
550
Graphite-grey screw
(25 off)
Tension band
The illustration shows EcoZenith
I
550
Fitting rear insulation and top cover
The rear insulation sections and top cover should be fitted before the CTC
EcoZenith C 530 or 510 is placed against a wall or in a corner for pipe and
electrical connection. These parts are delivered separately and they are
easier to fit if there is space around the unit.
Begin with the left rear insulation. Turn out the insulation, locate it in the
pockets in the front insulation and then turn it in against the tank. Repeat
this procedure for the right rear insulation. Note that the right rear insulation
needs to be turned out quite a lot for it to locate easily in the pockets.
When the rear insulation is in place, tension bands can be used to hold it
firmly against the tank. Attach the insulation sections to each other using the
25 graphite-grey screws provided. The screw holes are factory prepared.
!
The tension bands
can scratch the
surface of the insula-
tion. Use a piece of
cardboard or similar
to protect it.