22
CTC EcoFlex
End user information
Indoor Temp°C red -5
Here you can set how many degrees the room temperature is to be
lowered during the lower temperature periods. NB: –5 means that the room
temperature is lowered 5°C below the ordinary temp. If the room sensor
is not included in operation, the lowering is applied to the primary flow
temperature. Rule of thumb: a 3–4°C lower primary flow temperature gives
around 1°C lower room temp in a normal system.
WeekProgram or Block
Scheduling is set under these menus, see next section.
WeekProgram
Mon
▲
06
▼- - ▲- - ▼
22
Tue
▲
06
▼- - ▲- - ▼
22
Wed
▲
06
▼- - ▲- - ▼
22
Thu
▲
06
▼- - ▲- - ▼
22
Fri
▲
06
▼- - ▲- - ▼
23
Sat
▲
08
▼- - ▲- - ▼
23
Sun
▲
08
▼- - ▲- - ▼
22
3.8
Menu Week program
(Night reduction/WeekProgram)
Lowering times during days of the week can be scheduled in this menu.
The schedule repeats every week. The picture shows the factory values,
which can be changed. If further lowering periods are required, intermediate
times can be programmed.
▲
= the temperature is raised (to normal temp) at the times specified after
the arrow.
▼
= the temperature is lowered the number of degrees specified at the
time specified after the arrow.
Ex 1. Mon
▲
06
▼
- -
▲
- -
▼
22 :
On Monday morning at 6.00 am, the temperature is raised to normal and
remains normal throughout the day until 10.00 pm when the temperature is
lowered.
Ex 2. Mon
▲
06
▼
12
▲
16
▼
22 :
At 6:00 am, the temp is raised to normal, at 12:00 pm the temp is lowered
until 4:00 pm. Between 4:00 pm and 10:00 pm the temp is normal, after
which the temperature is lowered.
3.9
Menu Block
(Night reduction/Block)
Temperature lowering for several days of the week can be set in this menu.
For example, if you work somewhere else during the week but are at home
at the weekend.
Decr. Sunday 6:00 pm
Set the first day and time at which the temperature should be lowered.
Incr. Friday 4:00 pm
Set the day and time at which the temperature is to be returned to normal.
If two lowering periods are required in the week, they are programmed in
chronologic order.
E.g.:
Decr.
Sunday
6:00 pm
Incr.
Wednesday 4:00 pm
Decr.
Thursday
9:00 pm
Incr.
Friday
4:00 pm
Содержание ecoflex
Страница 2: ......
Страница 3: ...Installation and maintenance manual CTC EcoFlex Wood pellet boiler 162 105 01 4 2015 11 05 42 15 03 ...
Страница 53: ...53 CTC EcoFlex Installation 13 Electric diagram 230V 1N ...
Страница 54: ...54 CTC EcoFlex Installation 14 Electric diagram 400V 3N ...
Страница 56: ...56 CTC EcoFlex Installation Declaration of Conformity ...
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 60: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com ...