CTC EcoFlex
End user information
Settings
►
Lang.
English
Heat pump
No
Indoor sens
No
Boiler pellet °C
80
Alarm FlueGas °C
240
El Boiler °C
50
El boiler max kW
6,0
Max fuse A
20
External control
NR
Setting house Param
Setting pellet
Holiday off
Set. tank
Setting DHW
Save setting
Load setting
Load factory setting
Service
►
Functiontest pellets
Funktionstest other
Alarm info
Functiontest pellet
►
Auger Feeder
Off
Fan %
0
Auger burner %
0
El ignition
Off
Funct. test other
►
ElRelay 1,5/3 kW
0
ElRelay 3/6 kW
0
Pellet Off
Heatingcirpump.
Off
MixingValve Close
DHW pump
Off
Diode sensor
Off
Alarm stored
Last alarm
xxxxx
Stored alarm
xxxxx
xxxxx
xxxxx
xxxxx
Setting Heating
►
Max Primfl °C
55
Min Primfl °C
Off
Heating off
16
Heat curve
Inclination 50
Adjustment 0
Setting pellet
►
Level sensor %
0(50)
Flame detector %
99(50)
Burner type kW
15
Power full auger %
68
Power full fan %
40
Power part auger %
41
Power part fan %
20
Power min auger %
0
Power min fan %
0
Holding min
60
Auger Feeder s
30
Sequenz code
0
Time setting
Day
Thursday
Time
18:03
Stored oper data
Total operation h
8768
El heat kWh
1234
Pellet h
3456
Max prim °C
62
Cold starts
14
Warm starts
354
Night reduction
►
Activated
No/Yes
Type WeekProg
Indoor temp red °C
-2
Prim red °C
-5
WeekProgram
Installer
►
Settings
Service
Operation data
Outdoor °C
-5
Indoor °C
20(20)
Boiler °C
70
FlueGas °C
160
Primfl . °C
45(45)
▼
Operation data
▲
Current A
12(20)
Pellet startphase
1K
Mixingvalve close
Program ID
xxxxxxx
Program date
xx-xx-xx
Operation data
▲
Heatingcirc. pump
On
Elpower 3,0
▼
With indoor sensor
Without indoor sensor
With indoor sensor
Without indoor sensor
EcoFlex
Thurs 8:03
Indoor °C
20.0(20.0)
Indoor Temp
NR
Boiler °C
50
►
Operation data
Stored oper data
Night reduction
Installer
Indoor temp
-
●
●
●
●
+ (52)
Set. tank
►
Charge tank
Yes
Temp tank °C
70
Diff °C
5
Tank prio
No
3.5
Menu Operation data
(the menu is directly accessed from the main menu)
This menu displays current product and system temperatures and operating
data. Values in brackets are either required values or automatically
generated values which the product aims to achieve (set point).
Outdoor°C
-5
Displays current outdoor temperature. The product uses this value to
determine a number of different operating data.
Indoor°C
21 (21)
Displays current room temperature (if indoor sensor in operation is
selected), and required value “set point value” (in brackets).
Boiler°C
80
Displays the boiler temperature.
FlueGas °C
160
Displays current flue gas temperature.
Primfl. °C
35 (35)
Displays the temperature of the primary flow to the house’s heating system,
and the temperature which the system aims to achieve. This value will
vary during operation depending on set parameters and current outdoor
temperatures.
Heatingcir. pump
On
Displays the heating circuit (radiator) pump’s operating status. The pump
stops in the summer time when there is no heating requirement. The pump
is however exercised occasionally to avoid it jamming.
Elpower kW
0,0
Displays supplementary power supplied by the electric boiler (0…9 kW).
The electric boiler connects power in steps of 1,5 kW (6 connection steps).
(Only Swedish version)
Current A
7,3 (20)
Displays the house’s total current consumption on the hardest loaded
phase. The house’s main fuse size is displayed in brackets. Assumes that
the current sensor supplied has been fitted to the incoming cables. If the
current drawn exceeds the main fuse size, the electric boiler automatically
steps down a power step to protect the fuses, for example when several
high consumption equipment units in the house are being used.
(Only Swedish version)
Pellet Startph
1K
Displays the pellet burner’s current operating status
Shut off: Off: Start phase: Stop: Temp control: Full: Part: Min:
Mixingvalve Open
Displays whether the mixing valve valve increases/opens or reduces/closes
the heat supplied to the heating system. When the correct temperature has
been supplied, the valve solenoid then remains stationary.
Program ID
1011111
Control program identity.
Prog date
06-01-11
Control program version date.
Содержание ecoflex
Страница 2: ......
Страница 3: ...Installation and maintenance manual CTC EcoFlex Wood pellet boiler 162 105 01 4 2015 11 05 42 15 03 ...
Страница 53: ...53 CTC EcoFlex Installation 13 Electric diagram 230V 1N ...
Страница 54: ...54 CTC EcoFlex Installation 14 Electric diagram 400V 3N ...
Страница 56: ...56 CTC EcoFlex Installation Declaration of Conformity ...
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 60: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com ...