6
CTC VT 50 - 300
English
Storage and transport
The buffer tank must be stored in a dry and clean space.
CTC VT 50
CTC VT 100
CTC VT 200C
CTC VT 300C
Article number
589610001
589611001
589612001
589613001
Energy efficiency class
1)
C
C
C
C
Standing loss S
2)
W
46,0
67,0
71,0
89,0
Volume for storage
l
50,9
102,0
200,0
285,0
Connection dimensions
Height
mm
570
1010
1460
1500
Diameter
mm
454
454
570
670
Heating water inlet
G1 1/4
G1 1/4
G1 1/4
G1 1/4
Heating water outlet
G1 1/4
G1 1/4
G1 1/4
G1 1/4
Net/gross/weight with water
kg
16,5/18,5/66,5
29/31/131
55/67/255
71/84/356
Technical properties
Maximum allowable operating
pressure
MPa (bar)
1,0 (10)
1,0 (10)
0
,
6
(
6
)
0
,
6
(
6
)
Maximum water temperature
°C
95
Minimum water temperature,
cooling
°C
5
Non-enamelled sheet metal
+
+
+
+
Average insulation thickness
mm
33
33
59
67
Included in the delivery
Deaerator with valve G 1/2
+
+
-
-
Inlet ball valve G 1/2
+
+
-
-
Plug G1 1/4-Zn
-
-
+
+
Transport data
Packaging dimensions
mm
480x490x650
480x490x1100
680x760x1670
760x760x1710
Technical data
1) Commission Regulation EU 812/2013
2) Tested according to EN 12897:2006 or EN 60379:2005
Содержание 589610001
Страница 2: ......
Страница 82: ......
Страница 83: ......
Страница 84: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 500 80 1 2021 12 14...