8.  First start 

1.  Check that the heating boiler and system are full of water and have 

been bled.

2.  Check that all connections are tight.

3.  Check that sensors and the radiator pump are connected to the power 

source.

4.  Energise the heat pump by switching on the safety switch (the main 

switch).

Once the system has heated up, check that all connections are tight, the 

various systems have been bled, heat is coming out into the system and 

DHW is coming out at the tap locations.

9.  Operation and 

Maintenance

When the installer has installed your new heat pump, you should check 

along with the installer that the system is in perfect operating condition. Let 

the installer show you where the power switches, controls and fuses are 

so that you know how the system works and how it should be maintained. 

Bleed the radiators (depending on type of system) after around three days of 

operation and top up with water if required.

9.1  Periodic maintenance

After three weeks’ operation and then every three months during the first 

year. Then once a year:

•  Check that the installation is free of leaks.

•  Check that the product and system are free of air; bleed if needed – 

see the section 

Connection of brine system.

•  Check that the brine system is still pressurised and that the fluid level in 

the brine vessel is adequate/correct.

•  The products do not require annual inspection for refrigerant leakage.

9.2  Operation stop

The heat pump is shut down using the operating switch. If there is a risk of 

the water freezing, drain off all the water from the CTC EcoPart 600M.

Содержание 588600001

Страница 1: ...e energy solutions worldwide Installation and Maintenance CTC EcoPart 600M Modulating ground source heat pump Model 612M 616M 400 V 3N IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE REFERENCE 162...

Страница 2: ...h the carrying handles 6 Lift the cooling module using the carrying handles and shoulder straps 7 Lift the cooling module into the product using the carrying handles and shoulder straps Remove the car...

Страница 3: ...Installation and Maintenance CTC EcoPart 600M Modell 612M 616M 400 V 3N 162 305 09 2 14 08 2019...

Страница 4: ..._______18 5 1 3 Filling and venting_________________________________________19 5 1 4 Pressure level switch ____________________________________19 5 1 5 Post installation check on brine system ________...

Страница 5: ...it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Safety valve check Safety valve for boiler system to be checked regularly The produ...

Страница 6: ...CTC EcoZenith i550 Pro or to the existing heating system via the CTC EcoLogic control system CTC EcoPart 600M has been designed to operate with high efficiency and low noise levels Save this manual co...

Страница 7: ...on type of system for the flow required Open radiator valves depending on type of system and other relevant valves Tightness test Bleed the system Check proper operation of the requisite safety valves...

Страница 8: ...of the heat pump The heat pump must not be placed below floor level Avoid placing the heat pump in rooms where the walls are of lightweight design as people in the adjoining room may be disturbed by...

Страница 9: ...612M 616M CTC EcoLogic Pro Family CTC EcoZenith i550 Pro Control products must have software version or later CTC EcoZenith i550 Pro 2019 06 20 CTC EcoLogic Pro Family 2019 08 01 2 1 General Below ar...

Страница 10: ...wer Max starting current Compressor max operating current Max min fuse rating Enclosure class IP Other data Refrigerant quantity R407C fluorinated greenhouse gas GWP 1774 CO2 equivalent Interrupt valu...

Страница 11: ...x starting current Compressor max operating current Max min fuse rating Enclosure class IP Other data Refrigerant quantity R407C fluorinated greenhouse gas GWP 1774 CO2 equivalent Interrupt value swit...

Страница 12: ...side Brine 10 Drain valve warm side Water 11 Brine pump 12 Charge pump 13 Brine in 28 mm from rock 14 Brine out 28 mm to rock 15 Heat carrier out flow line 22 16 Heat carrier in return line 22 17 Dis...

Страница 13: ...13 CTC EcoPart 600M 3 4 Dimensions diagram 775 559 531 672 70 80 110 80 163 80 110 80 163 623 80 110 80 163 163 596...

Страница 14: ...hot gas 14 Temp brine 15 Temp water out 16 Temp water in 17 Control expansion valve 3 5 Refrigerant system Heat pump CTC EcoPart 600M Safety valve 1 2 3 bar Filter ball valve magnet 3 4 Filter ball v...

Страница 15: ...e this highest point with an automatic bleeder 4 1 1 Circulation Pumps Charging pumps G11 The following circulatory pumps are factory fitted CTC EcoPart 616M UPML XL GEO 25 125 130 PWM CTC EcoPart 612...

Страница 16: ...16 CTC EcoPart 600M CTC EcoPart 616M UPML XL GEO 25 125 130 PWM 1 x 230 V 50 60 Hz...

Страница 17: ...e the brine system is to be connected When the opening has been made through the cover plate carry out the installation as follows 1 In order to protect the brine hoses fasten the protective edging pr...

Страница 18: ...occur Always check the filter 99 when filling and bleeding the brine system The mixing ves sel and filling pump must be of an ade quate dimension 5 1 1 Valves To facilitate servicing of the cooling un...

Страница 19: ...me areas is for the system to be installed within a water catchment area If there is a leak the compressor and brine pump stop and the Flow level switch alarm appears on the controlling product s disp...

Страница 20: ...collector hoses constantly rise towards the heat pump If this is not possible it must be possible to bleed the system at the high points The filling pump usually copes with smaller local height discre...

Страница 21: ...r safety switch The installation should be preceded by an omnipolar safety switch according to overvoltage category III which ensures disconnection from all electric power sources The EcoPart 600M sho...

Страница 22: ...tion to the controlling product CTC EcoLogic or CTC EcoZenith i550 Pro ON 7 1 Alternative 1 Connection of one heat pump The communication cable of the heat pump LiYCY TP is connected directly to the r...

Страница 23: ...d in series the shielding of the communication cable on the last heat pump must be connected to earth and the heat pump itself must be terminated Make sure DIP switch 2 is in the ON position on the he...

Страница 24: ...is number instead 7 2 1 Define number of heat pumps Define the heat pumps in the controlling product s display under Advanced Define system Heat pump Set the heat pumps contained in the system to posi...

Страница 25: ...red and energised they should be displayed when you press the heat pump symbol in the menu Operational Info If any heat pump does not appear in the menu communication with the heat pump fails It may b...

Страница 26: ...26 CTC EcoPart 600M 7 4 Wiring diagrams 7 4 1 Cooling module A3...

Страница 27: ...27 CTC EcoPart 600M...

Страница 28: ...28 CTC EcoPart 600M 7 4 2 Cooling module A4...

Страница 29: ...29 CTC EcoPart 600M 7 4 3 Connection box 400 V 3N...

Страница 30: ...3 Brine sensor in Type 1 NTC B24 Brine sensor out Type 1 NTC B27 Heat pump in Type 2 NTC B28 Heat pump out Type 2 NTC B40 Sensor temp AC choke NTC 015 B100 High pressure sensor B101 Low pressure senso...

Страница 31: ...18 120 7 13 115 8 26 110 9 59 105 11 17 100 13 06 95 15 33 90 18 1 85 21 4 80 25 4 75 30 3 70 36 3 65 43 6 60 52 8 55 64 1 50 78 3 45 96 1 40 119 35 147 30 184 25 232 20 293 15 373 10 479 5 619 Temper...

Страница 32: ...ler show you where the power switches controls and fuses are so that you know how the system works and how it should be maintained Bleed the radiators depending on type of system after around three da...

Страница 33: ...to a materials or design fault then they will contact Enertech AB to check and rectify the issue Always provide the heat pump s serial number 10 1 Air problems If you hear a rasping sound from the hea...

Страница 34: ...34 CTC EcoPart 600M...

Страница 35: ...35 CTC EcoPart 600M...

Страница 36: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 305 09 2 14 08 2019 012...

Отзывы: