32
CTC 380 S
General information
Time programs
For the heating circuits and DHW heating, a number of switching program
are available. They are activated in “Automatic” operation and control the
change of the temperature levels via the selected switching times.
The switching times can be set in a combined way, that is, either commonly
for several days or separate times for individual days. When preselecting
groups of days like for instances Mo…Fr and Sa…Su that use the same
switching times, setting of the switching programs is simplifi ed.
• Press the ”OK-button”
• Select “Time prog heating circuit 1” and press “OK”.
• The text “Preselection” is shown.
• Press “OK” and the selection start fl ashing.
• You can select between program for Mo-Su, Mo-Fr, Sa-Su, or each
day separately
• Select “1 st phase on” and press “OK”.
• The time start fl ashing and you can select the start time for heating
“comfort setpoint” Press “OK”
• Select “1 st phase off” and press “OK”.
• The time start fl ashing and you can select the stop time for heating
“comfort setpoint” Press “OK”
• Phase off means that “Reduced setpoint” is active.
• It is possible to select 3 phase for each day.
• Press “ESC” and “ESC” again.
All time programs can be reset to the default settings. Each time program
has its own operating line to make this reset.
In that case, individual settings will be lost!