Chapter 3: Installing the PA PowerStation
Starting Up the PA PowerStation
PA PowerStation User Guide
37
Starting Up
the PA
PowerStation
Once the PA PowerStation has been mounted, you are ready to start up
the unit. This procedure is described below.
Before connecting a power cord to your unit, make sure that you have
read and understood Environmental Specifications on page 10 and the
Testing Specifications on page 12 of this manual. Also, be sure to
follow the guidelines listed below:
•
For permanently connected equipment, incorporate a readily
accessible disconnect device in the fixed wiring.
Important
Proper installation of this PowerStation model for use in
European Union countries requires the use of a harmonized
power cord (the power cord must be identified with the <HAR>
symbol). Make sure that the PowerStation is connected to the
main supply only with a harmonized power cord.
1.
Ensure the power on/off switch is in the off position.
2.
Connect the power cord to your voltage source. Voltage input to
the unit should be within the range specified in the Environmental
Specifications on page 10.
Note
Be sure to make DC connections.
3.
Connect the power cord plug to the PA PowerStation.
4.
Turn the PA PowerStation on.
The PowerStation will automatically load the MachineShop Shell
or an Interact application, if the Shell is configured to start
Interact automatically.
You are now ready to download a project to the PA PowerStation. If
you’re using MachineShop software, refer to the MachineShop
Getting Started Guide for information about downloading projects.