CTB Chore-Time QuadRadiant Скачать руководство пользователя страница 4

Page 4

1408 Quadradiant

The installation of this appliance must in all cases conform with local and national building
codes or in the absence of local codes with the current National Fuel Gas Code ANSI
Z223.1/NFPA 54, or the Natural Gas and Propane Installation Codes, CSA B149.1 and B149.2.

L'installation de cet appareil doit dans tous cas conforme avec les codes de bâtiment locaux et nationaux ou en l'ab-
sence de codes locaux avec le Carburant le Gaz le Code ANSI Z223.1/NFPA National actuel 54, ou le Gaz Naturels et
le Codes d'Installation de Propane, CSA B149.1, B149.2

La instalación de este aparato debe en todos casos se conforma con códigos locales y nacionales de edificio o en
ausencia de códigos locales con el Código Nacional actual de Gas de Combustible ANSI Z223.1/NFPA 54, o el Gas
natural y Códigos de Instalación de Propano, CSA B149.1, B149.2

DO NOT ALLOW POWER CORDS AND/OR GAS SUPPLY HOSES TO REST ON THE CANOPY,
HANGING BRACKETS OR OTHER HOT SURFACES OF THE UNIT OR TO COME WITHIN 12”
OF THE HEATER.

Ne pas permettre tuyaux à la provision de gaz de et/ou de cordes de pouvoir pour se reposer sur le baldaquin, pendant
des crochets ou les autres surfaces chaudes de l'unité Ou venir dans 12 › de l'appareil de chauffage.

No permita cuerdas de poder y/o mangas de suministro de gas para descansar en el dosel, colgando paréntesis u
otras superficies calientes de la unidad O para venir dentro de 12' de la calentadora..

Plug in the three-prong power cord to a correctly grounded three-prong electrical outlet.

Brancher sur le cordon d'alimentation de trois-broche à un a fondé correctement la trois-broche sortie électrique. 

Conecte la cuerda de tres polos del poder a un molió correctamente salida eléctrica de tres polos. 

Heaters must be electrically grounded in accordance with the National Electrical Code,
ANSI\NFPA 70 or the current Canadian Electrical Code, CSA C22.1. Polarity of Line voltage
and neutral wires must be maintained. The total load of all heaters in a circuit must be 
considered for overload control of that circuit.

Les appareils de chauffage doivent être électriquement fondé conformément au Code Electrique National, ANSI\NFPA
70 ou le Code Electrique, canadien et actuel, CSA C22.1. La polarité de tension de Ligne et de fils neutres doit être
maintenue. Le chargement total de tous appareils de chauffage dans un circuit doit être considéré pour le contrôle de
surcharge de ce 
circuit.

Las calentadoras basado en eléctricamente la conformidad con el Código Eléctrico Nacional, ANSI\NFPA 70 o el
Código Eléctrico, canadiense y actual, CSA C22.1. La polaridad del voltaje de la Línea y alambres neutrales se debe
mantener. La carga total de todas calentadoras en un circuito se debe considerar para el control de sobrecarga de ese
circuito. 

DSI UNITS MUST BE PROPERLY GROUNDED. DO NOT ALTER ELECTRICAL CORD. 

LES UNITES DE DSI DOIVENT ETRE CONVENABLEMENT FONDE. Ne PAS CHANGER LA CORDE ELECTRIQUE.

Las UNIDADES de DSI se DEBEN PONER EN TIERRA APROPIADAMENTE. No ALTERE CUERDA ELECTRICA.

Before lighting, sniff all around the appliance area for a gas odor. Be sure to sniff next to the
floor because propane gas is heavier than air and may temporarily exist at floor level.

Avant d'allumer, renifle tout autour le secteur d'appareil pour une odeur de gaz. Etre sûr de renifler à côté du plancher
parce que le gaz de propane est plus lourd que l'air et peut exister temporairement au niveau de plancher. 

Antes encender, huele por todas partes el área de aparato para un olor de gas. Esté seguro oler junto al gas de piso
porque propano está más pesado que aéreo y puede existir temporalmente en el nivel de piso.

16050056

Содержание Chore-Time QuadRadiant

Страница 1: ...y of its subsidiaries or divisions hereafter collectively referred to as CTB Subsequent changes to any manual made by any third party have not been reviewed nor authenticated by CTB Such changes may i...

Страница 2: ...Page 2 1408 Quadradiant Assembled in the U S A...

Страница 3: ...table means Example soap and water solution or a pressure check Do not use open flame to test for gas leaks Do not operate the heater until this test has been performed Use only the type of gas being...

Страница 4: ...ctrica de tres polos Heaters must be electrically grounded in accordance with the National Electrical Code ANSI NFPA 70 or the current Canadian Electrical Code CSA C22 1 Polarity of Line voltage and n...

Страница 5: ...lds are missing A See pages 18 21 in the installation and operation manual 7 Sensor Location Q Have you positioned your temperature sensors correctly A See page 14 in the installation and operation ma...

Страница 6: ...que ninguno falta A Vea las p ginas 18 21 7 Ubicaci n de sensor Q Ha colocado usted sus sensores de temperatura correctamente A Vea la p gina 14 8 Colgamiento Q Est n los puntos de suspensi n para sus...

Страница 7: ...TO BE INSTALLED BY CERTIFIED INSTALLERS ONLY ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THESE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER During normal operation the surfaces of the unit become ve...

Страница 8: ...E CONTACT PHYSIQUE ESTE APARATO TIENE CALOR DURANTE la OPERACION NORMAL EVITE el CONTACTO FISICO DANGER DO NOT ATTEMPT TO CLEAN THE HEATER WHILE IT IS OPERATING OR WHILE IT IS STILL HOT Ne PAS TENTER...

Страница 9: ...acturer requires the installation of the drip leg in order to help keep the gas orifice free from debris commonly found in gas lines Use approved certified and sealant on all connections Horizontal In...

Страница 10: ...The pressure should not drop below 4 5 P S I If the pressure does fall below 4 5 P S I then the gas distribution system is inadequately designed The problem may be a regulator pipe sizing etc GAS SUPP...

Страница 11: ...TER SAFETY CLEARANCE The heater must be located so there is a minimum clearance to combustible material of 24 minimum of 12 if heat deflectors are used above the heater and 48 from the side The heater...

Страница 12: ...Page 12 1408 Quadradiant...

Страница 13: ...heater Failure to follow these instructions could result in serious personal injury or significant property damage WARNING Failure to follow the instructions in this manual could result in serious per...

Страница 14: ...nsor should be placed over the feeder or drinker line Suspend sensor 12 to 16 off the floor Sensor should be no more than10 12 feet to the side from the center or 10 feet lengthwise from the center of...

Страница 15: ...winching make certain that ALL hoses and power supply cords are NOT resting on the heater nor are within 12 of the heater Hanging Points Pulleys should be mounted in the ceiling and posi tioned 6 wid...

Страница 16: ...inched up or down THIS HOSE INSTALLATION IS CORRECT The gas supply installation shown in the illustration above allows the gas supply hose to hang AWAY from the surfaces of the heater even during winc...

Страница 17: ...E INSTALLATION IS WRONG The gas supply hose is touching the heater More of the hose will rest on the heater during winching The gas supply hose is touching the heater More of the hose will rest on the...

Страница 18: ...Page 18 1408 Quadradiant Each unit requires two Left Deflectors and two Right Deflectors...

Страница 19: ...4308 Quadradiant Page 19 NOTE Narrow holed side of the deflectors face toward the outer side of the heater NOTE Full side of deflectors face to the center of the heater...

Страница 20: ...Page 20 1408 Quadradiant Align tabs of deflectors with slots on heater and insert tab into slots completely so that deflectors are flush against the unit...

Страница 21: ...4308 Quadradiant Page 21 Using pliers bend the tabs to secure deflectors to the heater Bend these tabs toward the outer edge Bend these tabs toward the inside...

Страница 22: ...l valve and burner assemblies Cover valve assembly with plastic before washing After wash downs remove plastic from heater We recommend that you light the heaters to dry up any excess moisture For pro...

Страница 23: ...120V 5P NAT 16550105 CONTROL ASM QDR 120V 5P LP See pages 26 27 for components 1 each 16050044 IGNITOR w BURNER MOUNT WIRE 1 each 16550086 SPACER BURNER INNER CONE SHORT 2 each 16550038 HEAT DEFLECTOR...

Страница 24: ...nt 16550081 CENTER SUPPORT CANOPY 1 each 16550080 END PLATE CONTROL END 1 each 16550079 END PLATE OPPOSITE CONTROL END 1 each 16550015 CANOPY 1 each 16550082 BOTTOM FLAME SHIELD 1 each 16550085 PAN CH...

Страница 25: ...5 16550093 BURNER ASM 1 each 16050046 INSULATION BOTTOM PANEL 1 each 16050047 INSULATION SIDE PANEL 2 each 16050048 INSULATION 2 each END PANEL 16550084 EMITTER PANEL QDRII 16550089 INNER CONE CORRUGA...

Страница 26: ...ach 16550091 HEAT SHIELD IGNITION CONTROL 1 each 16550083 BOX IGNITION CONTROL QDR II 1 each 16550055 CONTROL BOX LID QDR 1 each 10106615 HEYCO STRAIN RELIEF SR 7K 2 1 each 16050055 HOSE GAS 1 4ID 3 8...

Страница 27: ...TCH TOGGLE SINGLE POLE 1 each 16050049 MODULE IGNITION 120V BENNI 1 each 16000058 VALVE ASCO 120V 5PSI 1 each 16550087 AIR INTAKE NAT QDR 16550088 AIR INTAKE LP QDR 16050051 WIRE HARNESS 1 each PARTS...

Страница 28: ...1000683 BSHG 3 8 FPT X 1 2 MPT 1 3 13005228 PIPE NPL 1 2 CLOSE BLK 1 4 13004937 VALVE 1 2 BRASS BALL 1 5 13005193 PIPE NPL 1 2 X 3 BLK 1 6 13005229 PIPE CAP 1 2 BLK 1 Also included in the drip leg par...

Страница 29: ...4308 Quadradiant Page 29 120 VOLT WIRING DIAGRAM...

Страница 30: ...onsistent with excessive additions of chemicals minerals sediments or other foreign elements with the product shall not be considered defects under the Warranty 5 This Warranty applies only to systems...

Страница 31: ...4308 Quadradiant Page 31 N NO OT TE ES S...

Отзывы: