1408 Quadradiant
MAINTENANCE
Proper care and maintenance of your heater cannot be over emphasized!!
A POORLY MAINTAINED HEATER WILL:
- Raise Operating Costs- due to poor combustion.
- Lower Air Quality
- Cause Inconsistent Temperatures
- Decrease the Life of the Heater
MAINTENANCE PROGRAM
Daily: Check burner, flames should be burning clear and blue; if not, clean as required or check gas
pressure.
Clean heater after each flock.
Clean orifice using the CORRECT size orifice drill - 54 for LP and 51 for Natural Gas. Extreme care
must be taken not to enlarge or distort the orifice openings.
Clean dust and dirt from canopy, reflector pan, emitters and burner ports with compressed air. Blow
out the inside of the burner assembly using compressed air.
If houses are washed down, care should be taken to prevent moisture from accumulating on control
valve and burner assemblies. Cover valve assembly with plastic before washing.
After wash downs remove plastic from heater.
We recommend that you light the heaters to dry up any excess moisture.
For proper combustion it is important that the small holes in the emitter be clean and unobstructed.
The emitter can also be cleaned by inserting a long brass bristle brush between the screens and
inner cone.
Check ignitor and burner ports for debris, wipe clean with steel wool and clear burner ports with wire.
If heater is disconnected from the gas line, use tape to seal the open connections. This will keep
moisture, dust, and insects out and prevent future problems.
WARNING!
Never spray penetrating oil (WD-40) on the control valve. This will cause the loss
of high temperature valve grease and cause the valve to leak.
Failure to follow these instructions could result in serious personal injury or significant property
damage.
BEFORE PERFORMING ANY MAINTENANCE ON THE HEATER,
MAKE CERTAIN THAT ALL POWER AND FUEL HAS BEEN SHUT
OFF TO THE UNIT.
Содержание Chore-Time QuadRadiant
Страница 2: ...Page 2 1408 Quadradiant Assembled in the U S A...
Страница 12: ...Page 12 1408 Quadradiant...
Страница 18: ...Page 18 1408 Quadradiant Each unit requires two Left Deflectors and two Right Deflectors...
Страница 29: ...4308 Quadradiant Page 29 120 VOLT WIRING DIAGRAM...
Страница 31: ...4308 Quadradiant Page 31 N NO OT TE ES S...