USER'S MANUAL, VERSION 2.0
Copyright © Convergence Systems Limited 2021, All Rights Reserved
120
Example 3: GPO for Load Current < 160 mA (using +12V, 2 Watt Internal Isolated Power
Supply)
Inside CS463
LED lights up @ when
GPO_1 Switch becomes
Close
GPO_1
(+)
(Pin-4)
+12V(Pin-5)
GPO_1
(-)
(Pin-14)
GND (Pin-15)
I = 8.9 mA @ GPO_1=Close
1.2K
LED