-Reactr VS Location / Other Requirements-
• Locate the filter near a 120 volt / 60 Hz grounded electrical outlet.
• Check for distance and proper drain installation (e.g. floor drain, washing machine standpipe).
• Determine type and size of piping required for Reactr VS connection (e.g. galvanized, PVC plastic).
Note:
If household plumbing is galvanized and you intend to make an installation with copper (or vice versa), obtain
di-electric unions to prevent dissimilar metal corrosion.
Note:
Where the drain line is elevated above the control valve or exceeds 20' in length to reach the drain, use 3/4" I.D.
drain line tubing instead of 1/2" I.D. Drain line tubing is not included.
Caution:
When sweat soldering copper pipe (remember to always use lead free solder and flux), bypass valve with wet
rags to prevent heat damage to connections and control valve! If using PVC or plastic pipe, primers and solvent
cements specifically recommended for use with potable water are required.
Note:
All plumbing lines not requiring “filtered” water should be connected “upstream” of the A/P Tank.
(See Typical Installation Diagram.)
-Installation Procedure-
1. Position Reactr VS tank and Filter tank at the desired location. The Reactr VS tank must be installed between the
pump / pressure tank and filter tank. If a water softener is to be installed, it should be positioned after the filter tank.
2. The filter media is shipped separately from the filter tank and should be loaded prior to installation.
a) Remove control valve by unscrewing it from the filter tank.
b) Plug distributor with cap provided to prevent any media from entering the inside of the tube.
c) Place media funnel onto tank and fill tank 1/3 with water
d) Pour in media. Never fill tank more than 2/3 full to allow room for backwash. Since the Reactr VS comes
with a Vortech tank, gravel is NOT needed.
e) Remove cap and replace control valve.
3. Turn off main water supply and open nearest faucet to relieve pressure.
4. Cut main line and install the AP tank and Filter tank.
5. Turn on main water supply and allow water to flow through new plumbing and keep the nearest faucet open to
evacuate air.
6. Check for leaks.
7. If no leaks, proceed by slowly opening the bypass and allow water to fill the filter tank.
8. Allow water to run through the filter for a few minutes and then turn off the nearest faucet.
Caution:
Raised arrows located on the sides of control valve body and bypass valve indicate proper direction of
water flow. Install inlet and outlet piping in direction of arrows. It is recommended that a vacuum breaker be
installed on the inlet plumbing.
- Air Compressor / Relay Box –
• Locate the air compressor in close proximity to the AP tank assembly.
• Connect the supplied tubing to the compressor and the other end to the AP tank manifold insert.
• Insert the compressor’s electrical plug into the relay box.
• Insert the electrical plug from the relay box to an unswitched 120v / 60Hz grounded outlet.
• Attached by the relay box is a red and white RCA cable which plugs into the “B” (RED) and “S” (WHITE)outputs of the
control valve.
Note: As water flows through the filter, the meter will turn and send a signal to the relay box and the relay box will
turn on the air compressor. Make sure air compressor switch is turned on.