![CSI REACTR VS RF15VS-S2 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/csi/reactr-vs-rf15vs-s2/reactr-vs-rf15vs-s2_installation-and-operation-manual_2692679003.webp)
3
WARNING
Lubricants
Do NOT use Vaseline, oils, hydrocarbon lubricants or spray silicone anywhere! Petroleum base lubricants will cause
swelling of o-rings and seals. The use of other lubricants may attack plastic Noryl®. It is recommended that Dow Corn-
ing® silicone grease be used as a lubricant for all control valves. Dow Corning® 7 Release Compound is used in the
manufacture of Chandler Systems control valves. (Part # LT-150)
Sealants
Pipe dope and liquid thread sealers may contain a carrier that attacks some plastic materials. It is recommended that
Teflon® tape be used to seal plastic Noryl® threaded fittings.
Reactr VS Specifications
-How the Reactr VS Works_
The Reactr VS requires no chemicals for its operation. It consists of two components: (1) AP tank with air compressor and
(2) filter tank. The first item serves to oxidize and precipitate iron and sulfur so that the filter can later remove them. The
water flows down through the mineral bed of the filter and out the service lines. The collected precipitates must be reg-
ularly removed from the filter by reversing the flow of water through the filter running to drain. Called “backwashing” and
lasting 10 minutes, the process expands the mineral freeing the iron, sulfur, manganese and turbidity, which are washed
out of the filter to the drain. It is important that the correct amount of water is available for the Backwash Cycle. Check
pumping capacity to be certain water is available in sufficient volume to adequately backwash the equipment at the speci-
fied rate.
General Specifications
RF15VS-S2
RF15VS-S3
RF20VS-S2
RF20VS-S3
RF25VS-S2
RF25VS-S3
RF30VS-S2
RF30VS-S3
Filter Media Type
SmartBlend ™
Filter Media Capacity (cu ft)
1.50
2.00
2.50
3.00
REACTR ™
Tank (polyglass)
10 x 54
10 x 54
10 x 54
16 x 40
Mineral Tank (Vortech ™)
10 x 54
12 x 52
13 x 54
13 x 65
Service Flow Rate - Continuous (gpm)
5
6
8
9
Service Flow Rate - Intermittent (gpm)
7
8
10
11
Backwash Flow Rate (gpm)
5.0
6.0
7.0
7.0
Gallons Used / Backwash
100
120
140
140
Space Required - Filter Tank
10 x 10 x 62
10 x 10 x 62
10 x 10 x 62
16 x 16 x 73
Approximate Shipping Weight (lbs)
175
246
280
321
Note: Caution should always be used in sizing filters. Always choose a unit by satisifying the Backwash Requirement. Use of a flow control in the Service
Line is highly recommended. Consult the factory or your field sales person with questions. Oxyclean can be added to any existing Reactr or Reactr VS system.