4
Installation
-Installation Requirements-
A/P Tank
• A level floor position between the well pump and pressure tank. (See Typical Installation Diagram.)
• DO NOT install in an area of direct sunlight or where freezing temperatures may occur!
Filter Tank
• A level floor position ahead of piping into water heater.
• Unit must be installed at least 10’ ahead of the inlet to a water heater to prevent damage due to back-up of hot water.
• DO NOT install the unit in an area of direct sunlight or where freezing temperatures may occur! (See Typical
Installation Diagram.)
Relay Box
• Locate relay box near the filter tank and an unswitched 120v / 60 Hz grounded outlet
Note:
If household plumbing is galvanized and you intend to make an installation with copper or vice versa, obtain
dielectric unions to prevent dissimilar metal corrosion.
Where the drain line is elevated above the control valve or exceeds 20 ft. in length to reach the drain, use 3/4 in.
I.D. drain line tubing instead of 1/2 in.
When sweat soldering copper pipe, remember to always use lead free solder and flux. Cover yoke and bypass
valve with wet rags to prevent heat damage to connections and control valve. If using PVC or plastic pipe, primers
and solvent cements specifically recommended for use for potable water are required.
Always Follow Local Plumbing Codes.