Signature 2 

Signature 3

Reactr VS

Installation / Operation Manual

 

 

                                                                                                                                                 

                                                                                                                                         

Содержание REACTR VS RF15VS-S2

Страница 1: ...Signature 2 Signature 3 Reactr VS Installation Operation Manual ...

Страница 2: ...d Assy Sig 2 Sig 3 Page 14 Valve Body Assembly Sig 2 Page 15 Bypass Assembly Sig 2 Page 16 Valve Body Assembly Sig 3 Page 17 Bypass Assembly Sig 3 Page 18 Service Instructions Page 19 Troubleshooting Page 20 Error Codes Page 21 Warranty Information Page 22 FCC Compliance Statement http www chandlersystemsinc com files FCC_Compliance_Statement pdf Industry Canada Compliance Statement http www chand...

Страница 3: ...lter running to drain Called backwashing and lasting 10 minutes the process expands the mineral freeing the iron sulfur manganese and turbidity which are washed out of the filter to the drain It is important that the correct amount of water is available for the Backwash Cycle Check pumping capacity to be certain water is available in sufficient volume to adequately backwash the equipment at the sp...

Страница 4: ...an unswitched 120v 60 Hz grounded outlet Note If household plumbing is galvanized and you intend to make an installation with copper or vice versa obtain dielectric unions to prevent dissimilar metal corrosion Where the drain line is elevated above the control valve or exceeds 20 ft in length to reach the drain use 3 4 in I D drain line tubing instead of 1 2 in When sweat soldering copper pipe rem...

Страница 5: ...Plug distributor with cap provided to prevent any media from entering the inside of the tube c Place media funnel onto tank and fill tank 1 3 with water d Pour in media Never fill tank more than 2 3 full to allow room for backwash Since the Reactr VS comes with a Vortech tank gravel is NOT needed e Remove cap and replace control valve 3 Turn off main water supply and open nearest faucet to relieve...

Страница 6: ...drain for 3 to 4 minutes 3 Advance control valve to SERVICE cycle 0 position Electronic Connections P Power Supply B Powered in Backwash Step Only Cycle 1 S Powered based on Water Flow During Service Powered Backwash Cycle Installation Drain Line Connection 1 The drain line flow control assembly is pre assembled for your convenience Should you choose to hard plumb the drain line please remove the ...

Страница 7: ... 3 Default setting is 6 days for filters 5 To Exit Main Menu press the Menu Enter button Note If no buttons are pressed for 60 seconds the Main Menu will be exited automatically Control Start Up Procedures Final Checkout 1 Be certain that the bypass valve is in Service position and main valve is completely on 2 Check electrical supply to be certain the cord is connected to an uninterrupted 115 vol...

Страница 8: ...finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then restarts at that point when the power is restored The time will be offset by the increment of time the unit was without power so it is necessary to reset the time of day on the unit No other system will...

Страница 9: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve devices can be updated by the App When the app is updated from the Google Play Store or the Apple App Store it may contain an updated firmware program for the valve devices These updates could contain ...

Страница 10: ...ems in ORANGE with a set button can be changed For Filters Set Backwash Frequency This sets the amount of day between backwash cycles Change Time of Day Press SET to set time automatically based on device Set Regeneration Time Example For 2a m just type 2 choose a m and press OK Note If you have a filter and a softener the valves should be set to regenerate at different times Factory default times...

Страница 11: ...ep Option 2 Touch any graph to enlarge and see details Enlarged graphs are able to be zoomed in by pinching with two fingers Enlarged graph shown below Regenerate Unit at Next Regen Time button This will take the system into a backwash cycle at the next regeneration time Set Up Utilizing Bluetooth App Pressing the csv logo in the corner will allow the graph data to be exported and shared Enlarged ...

Страница 12: ... digits with the Set Change button and accept with the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Times Steps 1 2 3 4 Example 3 10 The next 4 displays set the duration of time in minutes for each backwash cycle step The step number which is currently modifiable is indicated on the far left of the display sc...

Страница 13: ...ront Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 21001X120 1 6 Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 20016X006 1 10 Lower Back Base for Cover 20111X003 1 11 Valve Cover 20111X000 1 12 Piston Screw 20001X003 1 13 Screw SC10 3 14 Screw SC9 2 15 Piston Washer 20001X002 1 16 Washer Circuit Board 20111X014 1 17 Screw Motor SC2 1...

Страница 14: ...on Part Number 1 1 4 Brass Hose Barb 65555X217 2 Vent Tube 3 4 OD X 1 4 ID X 12 65555X216 3 VS Manifold with O Ring 65555C007 4 Reactr Float Assembly 65555X210 5 Diffuser with Screws 65555X212 6 Manifold O Ring 20561X205 7 VS Check with 1 4 Tube X 1 4 NPT 68555X215 ...

Страница 15: ...ntrol Assy 6 0 GPM PVC 20017X263 1 Flow Control Assy 7 0 GPM PVC 20017X264 1 7 Drain Line Hose Barb 20017X235 1 8 Drain Retainer 20017X214 1 9 O Ring Brine Valve Cap Assembly 20001X230 1 10 O Ring Filter Plug Assembly 20001X229 1 11 10 24 X 1 Screw 20001X226 1 12 Injector Cap 20001X223 1 13 Injector Seal 20001X224 1 14 Injector Plug O Ring Assembly 20001X217 1 15 Valve O Ring 20561X205 1 16 Dist O...

Страница 16: ...16 Ref Description Part Qty 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless Steel 20561X283 1 1 2 Bypass Assembly Signature 2 ...

Страница 17: ...alve Body Assembly VH2 B D15 1 Ref Description Part Qty 1 Piston Assembly 20001X231 1 2 10 24 X 13 16 Screw 20001X226 3 3 Seal and Spacer Kit Incl 5 3 4 4 20561X253 1 4 End Spacer N S 1 5 Flow Control Button 5 0 GPM 20251X272 1 Flow Control Button 6 0 GPM 20251X274 1 Flow Control Button 7 0 GPM 20251X273 1 6 Plastic Flow Control Housing 20017X100 1 6A Flow Control Assy 5 0 GPM PVC 20017X262 1 Flow...

Страница 18: ...Part No 1 D15 Bypass 20017X283 2 1 Female Straight Slip Set optional 20017X288 3 1 NPT Elbow Set 20017X284 4 1 NPT Straight Set 20017X289 5a Elbow Vertical Adapter Blank optional 20017X295 5b Elbow Vertical Adapter 1 4 NPT Tapped optional 20017X294 ...

Страница 19: ...over C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer at piston drive yoke Remove powerhead mounting screws The entire powerhead assembly will now lift off easily 5 Remove piston retaining plate screws 6 Pull upward on end of piston yoke until assembly is ...

Страница 20: ...too slow or high service flow Check for media fouling 6 Loss of Water Pressure Scaling fouling of inlet pipe Clean or replace pipeline Pretreat to prevent Fouled media Clean media Pretreat to prevent Improper backwash setting Backwash more frequently 7 Continuous Flow to Drain Foreign material in control Call dealer Clean valve and replace piston and seals Internal control leak Same as above Valve...

Страница 21: ...valve body cycle power to clear the error code Manually cycle the powerhead through the regeneration cycle steps to verify that the motor can cycle properly while the powerhead is disconnected from the valve body If the error 3 does not reappear skip to step 3 below If the error 3 does reappear order a board motor kit to replace the circuit board motor 3 Remove piston and seals from the valve body...

Страница 22: ...22 Warranty ...

Страница 23: ...ulting from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water pressure not exceeding 125 psi oth er than CSI storage use operation accident or alteration lightning flooding or other environmental conditions To any failure or malfunction resulting from failure to keep th...