background image

    

30

WATER TREATMENT EQUIPMENT

This warranty cannot be transferred - it is extended only to the original 
purchaser  or first user of the product. by accepting and keeping this 
product, you agree to all of the warranty terms and limitations of liability 
described below.

Important  Warning: Read carefully the CSI Water Treatment Systems 
Equipment Installation, Operating and Maintenance Instructions Manual 
to avoid serious personal injury and property HAZARDS and to ensure 
safe and proper care of this product.

Model Numbers Covered:
Water Softeners, Media Filters and Upflow Filters

*FOR AS LONG AS YOU OWN AND LIVE IN YOUR SINGLE FAMILY 
HOME, this warranty covers your water treatment equipment, if you are 
the first user of this CSI Water Treatment Systems equipment and pur-
chased it for single family home use - subject to all of the conditions, lim-
itations and exclusions listed below. Purchasers who buy the CSI Water 
Treatment Systems equipment for other purposes, and other component 
parts are subject to more limited warranties and you should read all of the 
terms included in this form to make sure you understand your warranty.

What is covered by this warranty?
CSI Water Treatment Systems warrants that at the time of manufacture, 
the water treatment equipment shall be free from defects in material and 
workmanship as follows :

Product

Warranty

Residential Mineral Tank

10 Years

Proprietary Control Valves

7 Years

Other Softener / Filter Control Valves

5 Years

Brine Tank

5 Years

Residential Reverse Osmosis System

5 Years

Other Accessories and Parts

1 Year

Brine Tank Components

1 Year

REVERE Wireless Low Salt Alarm

90 Days

* This warranty does not include media and/or cartridge filter elements. 

Additional Terms & Conditions
What CSI Water Treatment Systems will do if you have a covered 
warranty claim CSI will at its option either make repairs to correct any 
defect in material or workmanship or supply and ship either new or used 
replacement parts or products. CSI will not accept any claims for labor or 
other costs.

Additional Exclusions and Limitations
This  warranty is non-transferable and does not cover any failure or prob-
lem unless it was caused solely by a defect in material or workmanship. 
In addition, this warranty shall not apply :

•  If  the water treatment equipment is not correctly installed, operated, 

repaired and maintained as described in the Installation, Operating & 
Maintenance Instructions Manual provided with the product.

•  Defects caused as a direct result of the incoming water quality

•  If the tank is not the size indicated for the supply line size of the instal-

lation, as described in the manual.

• 

To any failure or malfunction resulting from abuse (including freezing), 
improper or negligent; handling, shipping (

by 

anyone 

•  If the unit has not always been operated within the factory calibrated 

temperature limits, and at a water pressure not exceeding 125 psi oth-
er than CSI), storage, use, operation, accident; or alteration, lightning, 
flooding or other environmental conditions;

•   To any failure or malfunction resulting from failure to keep the unit full 

of potable water, free to circulate at all times; and with the tank free of 
damaging water sediment or scale deposits;

•  This warranty does not cover labor costs, shipping charges, service 

charges, delivery expenses, property damage, administrative fees or 
any costs incurred by the purchaser in removing or reinstalling the 
water treatment equipment.

•  The warranty does not cover any claims submitted to CSI more than 

30 days after expiration of the applicable warranty, and does not 
apply unless prompt notice of any claim is given to an authorized CSI 
Dealer or to CSI or a designated contractor is provided access to the 
installation and to the water treatment equipment.

THESE WARRANTIES ARE GIVEN IN LIEU OF ALL OTHER EXPRESS 
WARRANTIES. NO CSI REPRESENTATIVE OR ANY OTHER PARTY 
IS AUTHORIZED TO MAKE ANY WARRANTY OTHER THAN THOSE 
EXPRESSLY CONTAINED IN THIS WARRANTY AGREEMENT.

Additional Warranty Limitations
ANY IMPLIED WARRANTIES THE PURCHASER MAY HAVE, IN-
CLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BE-
YOND THE APPLICABLE TIME PERIODS SPECIFIED ABOVE. Some 
states do not allow limitations on how long an implied warranty lasts, so 
the above limitations may not apply to you.

Limitations of Remedies
The remedies contained in this warranty are the purchaser’s exclusive 
remedies. In no circumstances will CSI or the seller of the product be 
liable for more than, and purchaser-user’s remedies shall not exceed, 
the price paid for the product. In no case shall CSI or seller be liable for 
any special, incidental, contingent or consequential damages. Special, 
incidental, contingent and consequential damages for which CSI is not 
liable include, but  are not limited to, inconvenience, loss or damage to 
property, consequential mold damage, loss of profits, loss of savings 
or revenue, loss of use of the products or any associated equipment, 
facilities, buildings or services, downtime, and the claims of third parties 
including customers. Some states do not allow the exclusion or the limita-
tion of incidental or consequential damages, so the above limitations or 
exclusion may not apply to you.

What to do if you have a problem covered by this warranty
Any warranty coverage must be authorized by CSI. Contact the person 
from whom you purchased the product, who must receive authorization 
from a CSI Dealer .

If your product is new and not used and you wish to return it, contact your 
CSI Dealer.                               
 

Warranty

Содержание MS24-S2

Страница 1: ...Signature 2 Signature 3 Softener Manual Installation Operation Manual...

Страница 2: ...art Up Procedures Page 12 Master Programming Page 13 Utilizing Bluetooth Page 15 Control Valve Powerhead Assy Sig 2 Sig 3 Page 18 Valve Body Assembly Sig 2 Page 19 Bypass Assembly Sig 2 Page 21 Valve...

Страница 3: ...rains Capacity Regeneration Lbs Salt Used 24 000 12 20 000 7 5 15 000 4 5 32 000 15 27 000 9 20 000 6 48 000 24 40 000 15 30 000 9 64 000 30 54 000 18 40 000 12 96 000 45 81 000 27 60 000 18 Maximum R...

Страница 4: ...ft water The surfaces of these beads are covered with so dium ions As hard water enters the mineral tank and comes into contact with the resin an exchange of ions takes place as dissolved Calcium and...

Страница 5: ...tallation Requirements A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the inlet to a water heater to prevent damage due to back up of hot water DO...

Страница 6: ...included All plumbing lines not requiring soft water should be connected upstream of the softener The brine tank drain line is gravity flow and must discharge below the overflow fitting The brine over...

Страница 7: ...s and fill the mineral tank completely with water Replace the valve being careful to position the distributor tube into the distributor tube pilot hole Note If rebedding an existing unit and the syste...

Страница 8: ...valve or exceeds 20 feet in length 3 4 I D drain line tubing should be used Brine Line and Overflow Connection 1 Position brine tank on a smooth level surface near the softener resin tank If necessary...

Страница 9: ...uption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then restarts at that point when the power is restored The time wil...

Страница 10: ...e Set Change button Example A To accept the digit value press the Menu Enter button Once A M or P M is accepted the next menu item will flash 4 To set Hardness an H will appear to enter Compensated Ha...

Страница 11: ...ve step With Gallons Remaining Until Next Regeneration at 0000 Press and hold the Set Change button After 3 seconds the regeneration cycle will begin 3 To Fast Cycle thru regeneration First complete a...

Страница 12: ...l valve to automatically fill the brine tank Note Control valve will advance to service position automatically Disinfection For disinfection of your unit please follow the Sani System Procedure on the...

Страница 13: ...the scheduled time A setting of zero will cancel this feature Example Override every 7 days A 07 default setting or cancel setting A 00 Maximum is 29 3 Regeneration Cycle Step Times Steps 1 2 3 4 Exa...

Страница 14: ...o be used for lawn sprinkling or other similar uses 2 Servicing the water softener 3 A water leak from the water softener is evident 4 Shock treating water well and piping with chlorine or other disin...

Страница 15: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve d...

Страница 16: ...trol 1 Change Time of day Press set to set time automatically based on device time 1 Set Backwash Frequency 1 Set Regeneration Time This sets the amount of days between backwash cycles Example For 2am...

Страница 17: ...uctions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfer...

Страница 18: ...Softener Circuit Boad Assy 21001X102 1 2 Encoder 20001X124 1 3 Front Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 21001X120 1 6 Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower F...

Страница 19: ...19 Valve Body Assembly Signature 2...

Страница 20: ...1 4 End Spacer N S 1 5 Flow Control Button 1 2 GPM 20251X275 1 Flow Control Button 1 5 GPM 20251X266 1 Flow Control Button 2 0 GPM 20251X267 1 Flow Control Button 2 4 GPM 20251X268 1 Flow Control But...

Страница 21: ...gnature 2 Ref Description Part Qty 1A Meter Assembly Turbine Complete 20003X200 1 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless St...

Страница 22: ...22 2 9 1 3 13 14 12 16 17 18 19 21 22 10 11 4 5 6 7 6A 8 15 20 Valve Body Assembly Signature 3...

Страница 23: ...017X258 1 Flow Control Assy 3 0 GPM PVC 20017X259 1 Flow Control Assy 3 5 GPM PVC 20017X260 1 6 Drain Line Flow Control Housing Blank 20017X100 1 7 Drain Line Hose Barb Straight 20017X255 1 8 DLFC Cli...

Страница 24: ...1 Female Straight Slip Set optional 20017X288 3 1 NPT Elbow Set 20017X284 4 1 NPT Straight Set optional 20017X289 5a Elbow Vertical Adapter Blank optional 20017X295 5b Elbow Vertical Adapter 1 4 NPT T...

Страница 25: ...over C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer at...

Страница 26: ...m front of circuit board 3 Unscrew meter assembly nut from valve body 4 Remove meter from valve body and clean or replace as necessary 5 Reinstall meter nut and cable G To Replace Brine Valve 1 Follow...

Страница 27: ...over it Resin fouling Call dealer Find out how to confirm it Clean the resin and prevent future fouling Poor distribution channeling uneven bed surface Call dealer Check backwash flow Regenerate more...

Страница 28: ...n line and or flow control button Injector and or screen is plugged Clean or replace injector and screen No water in brine tank Check for restriction in BLFC Ensure safety float is not stuck Check bri...

Страница 29: ...ycle power to clear the error code Manually cycle the powerhead through the regeneration cycle steps to verify that the motor can cycle properly while the powerhead is disconnected from the valve body...

Страница 30: ...g from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water pressure not...

Страница 31: ...31...

Страница 32: ...32 CSI WATER TREATMENT SYSTEMS 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www csiwater com 11 17...

Отзывы: