background image

    

20

Ref 

#

Description

Part #

Qty.

11

Brine Line Ferrule

20251X305

1

12

Brine Line Compression Nut

N/S

1

13

10-24 X 1 Hex Screw

20001X226

1

14

Injector Cap

20001X223

1

14a Injectory Kit-Specify Size- Inc. 

(1) ea #14, #15, #16, #17 & (2) 
#13

20001X220

1

15

Injector Seal

20001X224

1

16

Injector Assy. Specify Size

20001X219

1

17

Injector Screen

20001X222

1

18

Injector Plug & O-Ring Assy.

20001X217

1

19

O-Ring

20561X205

1

20

O-Ring

20561X204

1

Ref 

#

Description

Part #

Qty.

1

Piston Assembly

20001X231

1

2

10-24 x 13/16 Screw

20001X226

3

3

Seal & Spacer Kit

20561X253

1

4

End Spacer

N/S

1

5

Flow Control Button 1.2 GPM

20251X275

1

Flow Control Button 1.5 GPM

20251X266

1

Flow Control Button 2.0 GPM

20251X267

1

Flow Control Button 2.4 GPM

20251X268

1

Flow Control Button 3.0 GPM

20251X269

1

Flow Control Button 3.5 GPM

20251X270

1

6

Plastic Flow Control Housing

20017X100

1

6a

Flow Control Assy. 1.2 GPM-
PVC

20017X275

1

Flow Control Assy. 1.5 GPM-
PVC

20017X256

1

Flow Control Assy. 2.0 GPM-
PVC

20017X257

1

Flow Control Assy. 2.4 GPM-
PVC

20017X258

1

Flow Control Assy. 3.0 GPM-
PVC

20017X259

1

Flow Control Assy. 3.5 GPM-
PVC

20017X260

1

7

Drain Line Fitting 1/2” NPT X 
1/2” 

20017X255

1

8

Drain Retainer

20017X214

1

9

Brine Assembly

20561X225

1

10

BLFC Assembly .5 GPM

20001X228

1

 

Valve Body Assembly - 

Signature 2

Содержание MS24-S2

Страница 1: ...Signature 2 Signature 3 Softener Manual Installation Operation Manual...

Страница 2: ...art Up Procedures Page 12 Master Programming Page 13 Utilizing Bluetooth Page 15 Control Valve Powerhead Assy Sig 2 Sig 3 Page 18 Valve Body Assembly Sig 2 Page 19 Bypass Assembly Sig 2 Page 21 Valve...

Страница 3: ...rains Capacity Regeneration Lbs Salt Used 24 000 12 20 000 7 5 15 000 4 5 32 000 15 27 000 9 20 000 6 48 000 24 40 000 15 30 000 9 64 000 30 54 000 18 40 000 12 96 000 45 81 000 27 60 000 18 Maximum R...

Страница 4: ...ft water The surfaces of these beads are covered with so dium ions As hard water enters the mineral tank and comes into contact with the resin an exchange of ions takes place as dissolved Calcium and...

Страница 5: ...tallation Requirements A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the inlet to a water heater to prevent damage due to back up of hot water DO...

Страница 6: ...included All plumbing lines not requiring soft water should be connected upstream of the softener The brine tank drain line is gravity flow and must discharge below the overflow fitting The brine over...

Страница 7: ...s and fill the mineral tank completely with water Replace the valve being careful to position the distributor tube into the distributor tube pilot hole Note If rebedding an existing unit and the syste...

Страница 8: ...valve or exceeds 20 feet in length 3 4 I D drain line tubing should be used Brine Line and Overflow Connection 1 Position brine tank on a smooth level surface near the softener resin tank If necessary...

Страница 9: ...uption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then restarts at that point when the power is restored The time wil...

Страница 10: ...e Set Change button Example A To accept the digit value press the Menu Enter button Once A M or P M is accepted the next menu item will flash 4 To set Hardness an H will appear to enter Compensated Ha...

Страница 11: ...ve step With Gallons Remaining Until Next Regeneration at 0000 Press and hold the Set Change button After 3 seconds the regeneration cycle will begin 3 To Fast Cycle thru regeneration First complete a...

Страница 12: ...l valve to automatically fill the brine tank Note Control valve will advance to service position automatically Disinfection For disinfection of your unit please follow the Sani System Procedure on the...

Страница 13: ...the scheduled time A setting of zero will cancel this feature Example Override every 7 days A 07 default setting or cancel setting A 00 Maximum is 29 3 Regeneration Cycle Step Times Steps 1 2 3 4 Exa...

Страница 14: ...o be used for lawn sprinkling or other similar uses 2 Servicing the water softener 3 A water leak from the water softener is evident 4 Shock treating water well and piping with chlorine or other disin...

Страница 15: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve d...

Страница 16: ...trol 1 Change Time of day Press set to set time automatically based on device time 1 Set Backwash Frequency 1 Set Regeneration Time This sets the amount of days between backwash cycles Example For 2am...

Страница 17: ...uctions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfer...

Страница 18: ...Softener Circuit Boad Assy 21001X102 1 2 Encoder 20001X124 1 3 Front Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 21001X120 1 6 Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower F...

Страница 19: ...19 Valve Body Assembly Signature 2...

Страница 20: ...1 4 End Spacer N S 1 5 Flow Control Button 1 2 GPM 20251X275 1 Flow Control Button 1 5 GPM 20251X266 1 Flow Control Button 2 0 GPM 20251X267 1 Flow Control Button 2 4 GPM 20251X268 1 Flow Control But...

Страница 21: ...gnature 2 Ref Description Part Qty 1A Meter Assembly Turbine Complete 20003X200 1 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless St...

Страница 22: ...22 2 9 1 3 13 14 12 16 17 18 19 21 22 10 11 4 5 6 7 6A 8 15 20 Valve Body Assembly Signature 3...

Страница 23: ...017X258 1 Flow Control Assy 3 0 GPM PVC 20017X259 1 Flow Control Assy 3 5 GPM PVC 20017X260 1 6 Drain Line Flow Control Housing Blank 20017X100 1 7 Drain Line Hose Barb Straight 20017X255 1 8 DLFC Cli...

Страница 24: ...1 Female Straight Slip Set optional 20017X288 3 1 NPT Elbow Set 20017X284 4 1 NPT Straight Set optional 20017X289 5a Elbow Vertical Adapter Blank optional 20017X295 5b Elbow Vertical Adapter 1 4 NPT T...

Страница 25: ...over C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer at...

Страница 26: ...m front of circuit board 3 Unscrew meter assembly nut from valve body 4 Remove meter from valve body and clean or replace as necessary 5 Reinstall meter nut and cable G To Replace Brine Valve 1 Follow...

Страница 27: ...over it Resin fouling Call dealer Find out how to confirm it Clean the resin and prevent future fouling Poor distribution channeling uneven bed surface Call dealer Check backwash flow Regenerate more...

Страница 28: ...n line and or flow control button Injector and or screen is plugged Clean or replace injector and screen No water in brine tank Check for restriction in BLFC Ensure safety float is not stuck Check bri...

Страница 29: ...ycle power to clear the error code Manually cycle the powerhead through the regeneration cycle steps to verify that the motor can cycle properly while the powerhead is disconnected from the valve body...

Страница 30: ...g from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water pressure not...

Страница 31: ...31...

Страница 32: ...32 CSI WATER TREATMENT SYSTEMS 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www csiwater com 11 17...