III. INSTALLATION CONDITIONS

 

PV module shall be used under the condition 
described hereinafter: 

 

(a) Mechanical condition 

1.  No vibration 
2.  No impact force 

 

(b) Electrical condition 

1.    Maximum system operation voltage: 

1000V for 

all 

series

 solar module

 

N (number of modules) =    Maximum                                               

system voltage of module/ Open circuit voltage of module at standard 
AM1.5G, 25 degrees temperature                                           

                                                 

condition, 

Maximum parallel modules=    The        

 

connector current rating(25A)/Maximum system current of module

 

If there are more than 2 strings, that   one string must be have a fuse, the fuse rating=the string

s current   

rating 

×

1.56

 

IV. INSTALLATION

 

 
 
 
 
 
 
 

 

 

 

 

 

 

 

(a) Unpack the module and check that the module’s glass surface is in good condition. 

 

(b) Check the Junction box at the rear side of module. You can open the cover by using a screwdriver as shown in 
Fig 2. Look over the cable connection polarity and the bypass diodes carefully (Fig 2), make sure they are in the 
right position and no any damage or loose parts. 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Fig  2.

 Use a screwdriver to open the lid of the Junction Box

 

 
 
 
 
 
 
 
 
 
 

Содержание CSG135M2-17/1482x674 series

Страница 1: ... Green Energy Industrial Park Xinji Village Machong Town Dongguan China Tel 86 769 88288015 Fax 86 769 88288160 www csgpvtech com CSG270M2 35 1956 992 series Please read this manual completely before installing or using the solar module ...

Страница 2: ...constitute a warranty CSG PVTech reserves the right to make changes to the product specifications or to the manual without prior notice II APPEARANCE The appearances and dimensions of the modules are as follows Series Power of each module Dimensions Fig NO CSG270M2 35 1956х992 280W 275W 270W 265W 260W 255W 250W 1956mm L x 992mm W x 50mm H Fig 1 a CSG230M2 30 1640 992 230W 225W 220W 215W 210W 1640m...

Страница 3: ...e at standard AM1 5G 25 degrees temperature condition Maximum parallel modules The connector current rating 25A Maximum system current of module If there are more than 2 strings that one string must be have a fuse the fuse rating the string s current rating 1 56 IV INSTALLATION a Unpack the module and check that the module s glass surface is in good condition b Check the Junction box at the rear s...

Страница 4: ...dules an example of acceptable mounting structure is shown in Fig 4 1 Prepare eight 8mm screws with washers and nuts on it Step A 2 Put the module on the mounting structure carefully one man holds the module and the others adjust the module to fit the mounting hole of module and mounting structure at the same level Screw the screws into the mounting holes and tighten the screws Step B Step C Step ...

Страница 5: ...g the modules to the battery or to other modules by the way of series connection or parallel connection Fig 5 Please use the same connector to connect with the modules Only the male and female connector can mate together Be careful of the system voltage and current when you connected the module together The voltage should not exceed the maximum system operation voltage limit ...

Страница 6: ...ghtning and related static discharge Ground the modules with equipment grounding screws Fig6 on each module and mounting rails or some equivalent grounding method The ground wire should be at least the same size as the electrical conductors An example of grounding method is shown in Fig 6 1 Prepare eight 4mm stainless screws with 4mm stainless star washers grounding conductor ground wire 4mm sprin...

Страница 7: ...ina Tel 86 769 88288015 Fax 86 769 88288160 www csgpvtech com Figure 6 Grounded module with screws f Wrong polarity cable connected will cause the bypass diode be destroyed and void the warranty g For a non integral module or panel the assembly is to be mounted over a fire resistant roof covering rated ...

Страница 8: ...protected PV modules must be protected so that the maximum series fuse rating printed on the listing label is not exceeded It is important to note that even though the listing label states fuse rating a more accurate term would be the maximum series overcurrent protection rating since either a fuse or a circuit breaker may be used to satisfy this listing requirement The module may be protected eit...

Страница 9: ... characteristic are within 10 percent of the indicated values of Isc Voc Pmax under Standard Test Conditions irradiance of 100mW cm2 AM1 5 spectrum and a cell temperature of 25 C 77 F The warranty condition is specified in the warranty card separately issued Parameters CSG270M2 35 1956 992 series Maximum power Pmax 280 275 270 265 260 255 250 Open circuit voltage Voc 44 7 44 6 44 5 44 3 44 0 43 8 ...

Страница 10: ...arameters CSG180M2 24 1324 992 series Maximum power Pmax 180 175 170 165 160 Open circuit voltage Voc 29 4 29 3 29 2 29 0 28 9 Short circuit current Isc 8 20 8 03 7 85 7 68 7 51 Maximum power voltage Vmp 23 6 23 4 23 2 23 1 23 1 Maximum power current Imp 7 62 7 48 7 33 7 14 6 92 Maximum system operation voltage V 1000 1000 1000 1000 1000 Application Class A A A A A Parameters CSG135M2 17 1482 674 ...

Страница 11: ...ical Installations Canadian Electrical Code Part 1 Any modules all have a serial number and a label the date and place of manufacture was marked on the label VIII CAUTION Never touch the end of output cables with bare hands when the module is irradiated Cover the surface of module by sufficiently thick cloth or something suitable to prevent incident light and handle the wires with rubber gloved ha...

Отзывы: