CSE SCSR TRAINING
December
2011 Do not remove or discard this page.
15
This
page is
important
for
Changeover
Plan Ahead
▸ You may need more than one
SCSR
to reach safety.
▸ Grab another
SCSR
as soon as possible.
Know When to Change Over to a Second SCSR
▸ When breathing gets uncomfortable: Change over!
▸ When breathing bag gets hard to fill: Change over!
How to Change Over
1
Open
second
SCSR
.
2
Hang
second
SCSR
around neck.
3
Pull
second
SCSR
’s starter tag.
4
Take deep breath from
first
SCSR
. Hold breath.
5
Pull
second
SCSR
’s mouthpiece plug.
6
Spit out
first
mouthpiece.
7
Put
second
SCSR
’s mouthpiece in mouth. Exhale.
8
Drop
first
nose clamp. Clamp nose shut with
second
clamp.
9
Drop
first
SCSR
after
second
one is working.
Model SRLD shown above;
instructions apply to both
SRLD and SR-
100
. Wear Model
SR-
100
with blue CSE logo
facing
away
from you.
SCSR
Basics
TRAINERS
|
MINERS
|
S
AFET
Y PERSONNEL