046121      

 

 

 

 

 

 

Model PROIWT Communication Interface

   

 

 

 

 

Revision: 

C

 

User Manual 

3

 

 

 

1.0   Cautions and Limitations 

  Failure to properly use and maintain this product could result in injury or death. 

  Never substitute, modify, add, or omit parts.  Use only exact replacement parts in the configuration as 

specified by Biomarine Inc. 

  The ongoing effectiveness and reliability of any protective breathing equipment is dependent upon the 

user/owner’s expertise in using and maintaining the equipment. 

  The user shall reference and abide by all cautions and limitation provided in the BioPak 240R 

respirator manuals. 

  The user shall reference and abide by all cautions and limitation provided in the Innovative Wireless 

Technologies (IWT) 

SENTINEL

TM

 Wireless Mesh Communication and Tracking System manuals. 

  The model PROIWT Communication Interface is suitable for use only with the Biomarine BioPak 

240R respirator and associated PRO PP facemask. 

  The PROIWT components have not been evaluated for use in applications involving direct open 

flame or high radiant heat. 

  The PROIWT components have not been evaluated for use in applications that may expose the user 

to chemical, biological, radiological, or nuclear agents (CBRN). 

  DO NOT attempt to fit the PROIWT Communication Interface to any other manufacture or model of 

respirator or facemask other than the BioPak 240R respirator or the PRO PP facemask. 

  The user bears full responsibility for properly maintaining this equipment including inspections, 

cleaning, maintenance, and care. 

  The facemask and installed PROIWT components shall be thoroughly cleaned and disinfected prior 

to each use. 

  If the respirator is going to be utilized without the services of the PROIWT communication interface it 

is strongly suggested to remove the interface components from the facemask and re-install the 

original facemask voice emitter front guard. 

  The PROIWT Communication Interface may be used with IWT Part Number FAA9100-411 speaker 

microphone only. 

  The PROIWT Communication Interface has been MSHA approved for intrinsic safety ONLY when 

properly interfaced with the following Innovative Wireless Technologies communication systems. 

SENTINEL

TM

 Wireless Mesh Communication and Tracking System 

MSHA Approval No:  23-A120005-0 

 

HEARING PROTECTION WARNING:

  This communications product is designed to produce a 

specific audio output level at a maximum rated power.  Many countries now have regulations defining 

the amount of noise that an individual can be subjected to during a normal workday.  The duration of 

exposure, and the level of ambient noise will affect compliance to these regulations.  Compliance is 

application dependent, and standards vary.  It is the SOLE RESPONSIBILITY of the end user to 

determine applicability of and compliance to local hearing protection regulations.

 

 

 

Содержание BIOMARINE PROIWT

Страница 1: ...sion C B5 06 6000 54 0 September 2021 Model PROIWT Communication Interface for PRO PP Facemask User Manual 1001 Corporate Lane Suite 240 Export PA 15632 USA Phone 412 856 9200 Fax 412 856 9203 https w...

Страница 2: ...ce Revision C User Manual 2 Table of Contents 1 0 Cautions and Limitations 3 2 0 MSHA Electrical Approval 4 3 0 Introduction 4 4 0 Installation 5 5 0 Communication System Use 7 6 0 Communication Syste...

Страница 3: ...irator or facemask other than the BioPak 240R respirator or the PRO PP facemask The user bears full responsibility for properly maintaining this equipment including inspections cleaning maintenance an...

Страница 4: ...HA approved interface component that will position a microphone into the speech outlet of a Biomarine PRO PP facemask A lapel mounted speaker will connect to the mask via either a 12 or 18 coax cable...

Страница 5: ...pplied with the Innovative Wireless Technologies communication system Warning Do not damage the voice emitter cup of the facemask during PROIWT installation The voice emitter located internal to the m...

Страница 6: ...voice emitter by pushing down on the release tab and pulling straight out Warning Do not damage the voice emitter cup of the facemask during PROIWT installation The voice emitter located internal to...

Страница 7: ...evision C User Manual 7 5 Install the trapezoid shaped foam piece into the open end of the vice emitter as depicted below Foam Insertion Foam Positioning 6 Reinstall the voice emitter into the mask ma...

Страница 8: ...ion C User Manual 8 7 Reinstall the nose cup around the perimeter of the voice emitter as depicted below If the mask is fitted with a drink tube make sure the drink tube is properly positioned as depi...

Страница 9: ...g the four Torx screws from step 1 Hand tighten the screws evenly and DO NOT OVER TIGHTEN 10 Don the facemask and determine which microphone cable is best suited for the user The microphone cable will...

Страница 10: ...an then be powered on restoring normal operations b Remove any dust caps or covers from the radio cable connector c Attach the speaker radio cable to the radio connector d Tighten the mounting thumbwh...

Страница 11: ...s within the interface component cables or speaker Do not disassemble the components or the validity of the MSHA intrinsic safety approval will be voided The front grill of the speaker can be removed...

Страница 12: ...nterface Complete 1 B6 02 5003 61 1 Mask Interface Component 2 B6 01 5000 18 0 Microphone Cable 12 3 B6 01 5000 19 0 Microphone Cable 18 4 B2 06 6002 87 0 Speaker Radio Cable 5 B2 06 6002 88 0 Optiona...

Страница 13: ...046121 Model PROIWT Communication Interface Revision C User Manual 13 This page intentionally left blank...

Отзывы: