6.0   Communication System Post Use 

At the completion of a mission, follow all instruction provided by Innovative Wireless Technologies to shut 

down the Innovative Wireless Technologies 

SENTINEL

TM

 Wireless Mesh Communication and Tacking 

System.  Remove the microphone cable from the interface and remove the speaker and radio from the 

user.  The interface should remain installed in the facemask.  Cover the connectors of the interface with 

the supplied cap to protect.  Wash and inspect the facemask as described in the BioPak 240R Benchman 

Manual.  Be sure that contacts of the interface connector are fully dry prior to reuse. 

Warning:

 

Make sure the contactors of the interface connector are fully dry before re-using the 

facemask. 

Warning: 

When not in use, keep the contactors of the interface protected by covering with the 

included cap. 

Warning:

 

Do not allow the facemask with the interface installed to soak in disinfectant or remain 

submerged in liquid for extended periods.  Ten minutes is all that is required to fully 

disinfect the mask. 

Warning:

 

There are no servable parts within the interface component, cables, or speaker.  Do 

not disassemble the components or the validity of the MSHA intrinsic safety approval 

will be voided. 

The front grill of the speaker can be removed for cleaning if needed.  To remove the front grill, grip the 

speaker in one hand, use the palm of the other hand to press down on grill and turn ¼ turn to the left.  

Grill will lift out of housing.  Grill can be removed to wipe away dust, dirt, moisture, etc. from inside the 

cavity to ensure optimum performance.  An optional debris screen, part number B2-06-6002-88-0, may be 

located under the front grill and is used in those environments with intense conditions.  The debris screen 

can be washed with warm soapy water and replaced, when completely dry, back into the unit. 

Removable Front Grill of Speaker 

To remove the front grill of the speaker, reference Illustrated Parts List, grip speaker in one hand, use 

palm of other hand to press down on grill and turn ¼-turn to the left.  Grill will lift out of housing.  Grill can 

be removed to wipe away dust, dirt, moisture, etc. from inside cavity to ensure optimum performance.  An 

optional debris screen, B2-06-6002-88-0, may be located under the front grill for use in environments with 

intense conditions.  The debris screen can be washed with warm soapy water and replaced, when 

completely dry, back into the speaker. 

 

 

Содержание BIOMARINE PROIWT

Страница 1: ...sion C B5 06 6000 54 0 September 2021 Model PROIWT Communication Interface for PRO PP Facemask User Manual 1001 Corporate Lane Suite 240 Export PA 15632 USA Phone 412 856 9200 Fax 412 856 9203 https w...

Страница 2: ...ce Revision C User Manual 2 Table of Contents 1 0 Cautions and Limitations 3 2 0 MSHA Electrical Approval 4 3 0 Introduction 4 4 0 Installation 5 5 0 Communication System Use 7 6 0 Communication Syste...

Страница 3: ...irator or facemask other than the BioPak 240R respirator or the PRO PP facemask The user bears full responsibility for properly maintaining this equipment including inspections cleaning maintenance an...

Страница 4: ...HA approved interface component that will position a microphone into the speech outlet of a Biomarine PRO PP facemask A lapel mounted speaker will connect to the mask via either a 12 or 18 coax cable...

Страница 5: ...pplied with the Innovative Wireless Technologies communication system Warning Do not damage the voice emitter cup of the facemask during PROIWT installation The voice emitter located internal to the m...

Страница 6: ...voice emitter by pushing down on the release tab and pulling straight out Warning Do not damage the voice emitter cup of the facemask during PROIWT installation The voice emitter located internal to...

Страница 7: ...evision C User Manual 7 5 Install the trapezoid shaped foam piece into the open end of the vice emitter as depicted below Foam Insertion Foam Positioning 6 Reinstall the voice emitter into the mask ma...

Страница 8: ...ion C User Manual 8 7 Reinstall the nose cup around the perimeter of the voice emitter as depicted below If the mask is fitted with a drink tube make sure the drink tube is properly positioned as depi...

Страница 9: ...g the four Torx screws from step 1 Hand tighten the screws evenly and DO NOT OVER TIGHTEN 10 Don the facemask and determine which microphone cable is best suited for the user The microphone cable will...

Страница 10: ...an then be powered on restoring normal operations b Remove any dust caps or covers from the radio cable connector c Attach the speaker radio cable to the radio connector d Tighten the mounting thumbwh...

Страница 11: ...s within the interface component cables or speaker Do not disassemble the components or the validity of the MSHA intrinsic safety approval will be voided The front grill of the speaker can be removed...

Страница 12: ...nterface Complete 1 B6 02 5003 61 1 Mask Interface Component 2 B6 01 5000 18 0 Microphone Cable 12 3 B6 01 5000 19 0 Microphone Cable 18 4 B2 06 6002 87 0 Speaker Radio Cable 5 B2 06 6002 88 0 Optiona...

Страница 13: ...046121 Model PROIWT Communication Interface Revision C User Manual 13 This page intentionally left blank...

Отзывы: