iKey Interface  

 

CS Controller and Software Configuration 

 
 

Wiegand  Format: 

 

CONTROLLER: 

Set appropriate controller  links 
 
LK19, LK18, LK17, LK8, LK20 – OFF 
LK21 – DOWN, LK22 – UP (+V = 5 volts) 
 

Reader on Port 1:

 LK20 ON 

Reader on Port 2:

 LK19, LK18 - ON 

Reader on Port 3 &/or 4:

 LK17, LK8 – ON 

 
 

SOFTWARE: 

Set the controller type as ‘CARD’. 
 

 

 
Set the reader type as ‘WIEGAND’. 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

Clock + Data  Format: 

 

CONTROLLER: 

Set appropriate controller  links 
 
LK19, LK18, LK17, LK8, LK20 – OFF 
LK21 – DOWN, LK22 – UP (+V = 5 volts) 
 

Reader on Port 1:

  no link changes 

Reader on Port 2:

 LK19 - ON 

Reader on Port 3 &/or 4:

 LK17 – ON 

 
 

SOFTWARE: 

Set the controller type as ‘CARD’. 
 

 

 
Set the reader type as ‘CLOCK + DATA’. 
 

 

 
Set the magstipe card parameters as shown below and tick 
‘Wiegand type sitecode and card number’ 
(‘Hardware/Site/Edit Card Option’) 

 

 
 

 

Содержание iKey

Страница 1: ...urity system without compromising security in any way Features Dedicated single purpose controller no programming necessary Easy installation On board links select either wiegand clock and data or RS232 output The interface has an internal ID number which must match that in all keys presented to it for them to be recognised Once this ID is validated then the sitecode and card number within the key...

Страница 2: ... removed When there is a link here the red LED on the controller should flash quickly Touching a valid CS Technologies iKey to the reader will cause the internal ID to be set to match the key and the interface will beep very quickly twice Now the link can be removed and the reader will recognise keys with that same internal ID Before powering up the interface board Unit installed in dry secure loc...

Страница 3: ...t 2 LK19 LK18 ON Reader on Port 3 or 4 LK17 LK8 ON SOFTWARE Set the controller type as CARD Set the reader type as WIEGAND Clock Data Format CONTROLLER Set appropriate controller links LK19 LK18 LK17 LK8 LK20 OFF LK21 DOWN LK22 UP V 5 volts Reader on Port 1 no link changes Reader on Port 2 LK19 ON Reader on Port 3 or 4 LK17 ON SOFTWARE Set the controller type as CARD Set the reader type as CLOCK D...

Страница 4: ... 5V GND Host panel connections LK1 ON store iKey ID in reader JP3 must also be off LK1 OFF normal operation LED open collector drive LK2 3 4 always off NC1 C1 NO1 NC2 C2 NO2 12V 0V 5V GND IN1 IN2 IN3 IN4 LED2 LED1 93C66 LK5 LK4 LK3 LK2 LK1 JP3 JP3 ON RS232 format JP3 OFF non RS232 format Note JP3 must be OFF to set the internal ID RS232 format JP3 on TX ...

Отзывы: