                                            Installation Guide

 

General 

 
The CS Technologies iKey Interface is a small, low-cost 
interface between the CS Technologies ‘iKey’ and a wide 
range of security equipment. It produces either ‘Wiegand’, 
‘Clock and Data’ or ‘RS232’ output. 
 
Inside each iKey is an encrypted site code and card number, 
together with a reader ID. Each iKey is guaranteed to be 
unique world-wide, ensuring extremely high security. 
 
The iKey Interface verifies the validity of the key which is 
being presented to the reader, and if it is a valid key for that 
site (i.e. has a valid reader ID) transmits a Site Code and Card 
Number as either 
-

 

a standard 26-bit Wiegand string (8-bit site code plus 16-
bit card number, or 

-

 

a 10-digit BCD-format ABA-encoded clock and data 
string (track 2 magstripe format) (5 digit site  code, 5 digit 
card number), or 

-

 

a 10-digit RS232 string terminated with a carriage 
return/line feed at 9600 baud (5 digit site code, 5 digit 
card number) 

 
The Interface  can be used to interface to any access control, 
alarm or RS232 host system which supports industry-standard 
data formats. This is achieved in conjunction with complete 
security because of the unique reader ID which provides an 
additional layer of security. 
 
With the Interface the durability, long-life, low cost and 
convenience of the iKey and its stainless steel reader can be 
linked with any other suitable security system, without 
compromising security in any way. 
 

Features 

 

‰

 

Dedicated single-purpose controller; no programming 
necessary. 

‰

 

Easy installation 

‰

 

On-board links select either wiegand, clock-and-data or 
RS232 output 

‰

 

The interface has an internal ID number which must 
match that in all keys presented to it for them to be 
recognised. Once this ID is validated then the sitecode 
and card number within the key is sent to the host. In this 
way the relatively low-security Wiegand format is 
transformed to an extremely high security, encrypted and 
traceable format. 

‰

 

Requires iKeys programmed in CS Technologies format. 

‰

 

Operates from 12VDC or 5VDC supplied by security 
panel; no additional power supply required 

‰

 

Allows the durable iKey and reader to be used with other 
security panels or serial hosts in standard format. 

‰

 

Extremely reliable operation 

‰

 

100% Australian made and designed 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Specifications 
 

Power supply 

12VDC or 5VDC 

Current Consumption 

50mA max (interface only) 

Temperature range 

0

°

C to 70

°

Humidity range 

0 to 95% relative noncondensing 

Dimensions Box: 

86x66x30mm 

Board: 80x60x28mm 

Shipping weight 

300g 

Housing 

High impact ABS plastic box 
with bulkhead mounting lugs 

Reader interface 

Silicon Key (one-wire) interface 

Output 
 
 
The encoded sitecode 
and card number are 
transmitted from the 
interface only if the key 
is valid for that reader, 
verified by an encoded 
unique ID. 

Link-selectable 
a)

 

Standard 26-bit Wiegand 
format (LK5 link on).  Start 
bit, 8 bit sitecode, 16-bit card 
number, stop bit 

b)

 

Mag-stripe (ABA) format 
(LK5 link off). Start sentinel, 
5 digit site code, 5 digit card 
number, end sentinel. 

c)

 

RS232 format (JP3 link on). 5 
digit site code, 5 digit card 
number, 9600 baud, no 
handshaking, CR/LF 
terminated. 

 

 
 

Содержание iKey

Страница 1: ...urity system without compromising security in any way Features Dedicated single purpose controller no programming necessary Easy installation On board links select either wiegand clock and data or RS232 output The interface has an internal ID number which must match that in all keys presented to it for them to be recognised Once this ID is validated then the sitecode and card number within the key...

Страница 2: ... removed When there is a link here the red LED on the controller should flash quickly Touching a valid CS Technologies iKey to the reader will cause the internal ID to be set to match the key and the interface will beep very quickly twice Now the link can be removed and the reader will recognise keys with that same internal ID Before powering up the interface board Unit installed in dry secure loc...

Страница 3: ...t 2 LK19 LK18 ON Reader on Port 3 or 4 LK17 LK8 ON SOFTWARE Set the controller type as CARD Set the reader type as WIEGAND Clock Data Format CONTROLLER Set appropriate controller links LK19 LK18 LK17 LK8 LK20 OFF LK21 DOWN LK22 UP V 5 volts Reader on Port 1 no link changes Reader on Port 2 LK19 ON Reader on Port 3 or 4 LK17 ON SOFTWARE Set the controller type as CARD Set the reader type as CLOCK D...

Страница 4: ... 5V GND Host panel connections LK1 ON store iKey ID in reader JP3 must also be off LK1 OFF normal operation LED open collector drive LK2 3 4 always off NC1 C1 NO1 NC2 C2 NO2 12V 0V 5V GND IN1 IN2 IN3 IN4 LED2 LED1 93C66 LK5 LK4 LK3 LK2 LK1 JP3 JP3 ON RS232 format JP3 OFF non RS232 format Note JP3 must be OFF to set the internal ID RS232 format JP3 on TX ...

Отзывы: