f. For a positive-grounded vehicle, connect the negative (black) clip from the battery charger to
negative battery post first, then connect the positive (red) clip from the battery charger to the vehicle
chassis or engine block remote from the battery and fuel line.
g. If using permanently mounted eyelet lead SAE connector, simply connect to charger output lead.
h. Connect charger AC supply cord to an electric outlet.
I. When disconnecting the charger, disconnect AC cord, remove clip from vehicle chassis, and then
remove clip from battery terminal.
j. See operating instructions for length of charge information.
2) Follow these steps when battery is outside the vehicle. A spark near the battery may cause an
explosion, reduce risk of a spark near battery.
a. Check polarity of battery posts. A positive (+) battery post may have a larger diameter than a
negative (-) post.
b. Attach at least 1.8m long 1.5mm² insulated battery output cable charger to the negative (-) battery
post.
c. Connect the positive (red) clip from the battery charger to the positive (+) battery post.
d. Position yourself and the free end of cable as far away from battery as possible, then connect
negative (black) clip from the battery charger to free end of cable.
e. Do not face battery when making final connection.
f. Connect charger AC supply cord to an electric outlet.
3) When disconnecting the charger, always do so in reverse sequence of connecting procedure and
break first connection while standing as far away from battery as practical. A marine (boat) battery
must be removed and charged on shore, to charge it on the boat requires equipment specially
designed for marine use.
OPERATING INSTRUCTIONS
AUTOMATIC MONITORING
- Your new battery charger is completely automatic and can be left on
whenever input power is made available to the charger. The charger output depends on the condition of
the battery it is charging. When the battery is fully charged, the "Good" will indicate and battery indicator
will show "100%", then the charger will switch itself to a storage charge mode and will automatically
monitor and maintain the battery at full charge.
CABLE CONNECTIONS
- Your new battery charger is equipped with two output leads, a red positive
lead, and a black negative clip lead and a permanent mount eyelet lead with a 2 pin SAE connector.
Always connect or disconnect the output leads before plugging into AC power.
For all battery types: Connect the red positive (+) lead to the positive terminal of the battery. Connect the
black negative (-) lead to the negative terminal of the battery.
NOTE:
If the charger is left connected to a lead acid battery for long periods of time, check water levels
periodically as directed by the battery manufacturer to ensure electrolyte is maintained at proper level
ATTENTION: THE BATTERY CHARGER HAS A SPARK FREE AND REVERSE POLARITY
PROTECTION. AS A GOOD PRACTICE, NEVER ALLOW THE TWO CLIPS TOUCH EACH OTHER
The battery charger will not produce voltage (turn on) until it recognizes at least two volts from the
battery. The battery charger clips must be clipped to a battery in the correct polarity to initiate output
voltage and begin charging when in Lead Acid (Pb) charge mode.
When in Lead Acid (Pb) charge mode if the charger is hooked up in reverse polarity, the red "Reverse
Polarity" light will flash, indicating that the connection has been made in reverse of the polarity of the
battery and a charge has not been initiated. The clips must be re-connected in the proper polarity to start
the charger, Red to positive (+ to +) and Black to Negative (-to-)
NOTE: DO NOT TURN YOUR BATTERY CHARGER ON AND OFF REPEATEDLY (Plug and Unplug)
WITHIN A SHORT PERIOD. IF THIS HAPPENS, UNPLUG BATTERY CHARGER FROM AC POWER,
WAIT FOR ONE MINUTE AND THEN CONNECT THE CHARGER AGAIN TO RESTART CHARGING