background image

  f. For a positive-grounded vehicle, connect the negative (black) clip from the battery charger to 

negative battery post first, then connect the positive (red) clip from the battery charger to the vehicle 
chassis or engine block remote from the battery and fuel line.

  g. If using permanently mounted eyelet lead SAE connector, simply connect to charger output lead. 
  h. Connect charger AC supply cord to an electric outlet. 
  I. When disconnecting the charger, disconnect AC cord, remove clip from vehicle chassis, and then 

remove clip from battery terminal. 

 

j. See operating instructions for length of charge information. 

2) Follow these steps when battery is outside the vehicle. A spark near the battery may cause an 

explosion, reduce risk of a spark near battery. 

 

a. Check polarity of battery posts. A positive (+) battery post may have a larger diameter than a 

negative (-) post. 

 

b. Attach at least 1.8m long 1.5mm² insulated battery output cable charger to the negative (-) battery 

post. 

 

c. Connect the positive (red) clip from the battery charger to the positive (+) battery post. 

 

d. Position yourself and the free end of cable as far away from battery as possible, then connect 

negative (black) clip from the battery charger to free end of cable. 

 

e. Do not face battery when making final connection. 

 

f. Connect charger AC supply cord to an electric outlet. 

3) When disconnecting the charger, always do so in reverse sequence of connecting procedure and 

break first connection while standing as far away from battery as practical.  A marine (boat) battery 
must be removed and charged on shore, to charge it on the boat requires equipment specially 
designed for marine use. 

OPERATING INSTRUCTIONS 

AUTOMATIC MONITORING

 - Your new battery charger is completely automatic and can be left on 

whenever input power is made available to the charger. The charger output depends on the condition of 
the battery it is charging. When the battery is fully charged, the "Good" will indicate and battery indicator 
will show "100%", then the charger will switch itself to a storage charge mode and will automatically 
monitor and maintain the battery at full charge.

CABLE CONNECTIONS 

- Your new battery charger is equipped with two output leads, a red positive 

lead, and a black negative clip lead and a permanent mount eyelet lead with a 2 pin SAE connector. 
Always connect or disconnect the output leads before plugging into AC power.
For all battery types: Connect the red positive (+) lead to the positive terminal of the battery. Connect the 
black negative (-) lead to the negative terminal of the battery. 

NOTE: 

If the charger is left connected to a lead acid battery for long periods of time, check water levels 

periodically as directed by the battery manufacturer to ensure electrolyte is maintained at proper level 

ATTENTION: THE BATTERY CHARGER HAS A SPARK FREE AND REVERSE POLARITY 
PROTECTION. AS A GOOD PRACTICE, NEVER ALLOW THE TWO CLIPS TOUCH EACH OTHER

The battery charger will not produce voltage (turn on) until it recognizes at least two volts from the 
battery. The battery charger clips must be clipped to a battery in the correct polarity to initiate output 
voltage and begin charging when in Lead Acid (Pb) charge mode.
When in Lead Acid (Pb) charge mode if the charger is hooked up in reverse polarity, the red "Reverse 
Polarity" light will flash, indicating that the connection has been made in reverse of the polarity of the 
battery and a charge has not been initiated. The clips must be re-connected in the proper polarity to start 
the charger, Red to positive (+ to +) and Black to Negative (-to-) 

NOTE: DO NOT TURN YOUR BATTERY CHARGER ON AND OFF REPEATEDLY (Plug and Unplug) 
WITHIN A SHORT PERIOD. IF THIS HAPPENS, UNPLUG BATTERY CHARGER FROM AC POWER, 
WAIT FOR ONE MINUTE AND THEN CONNECT THE CHARGER AGAIN TO RESTART CHARGING 
CYCLE

Содержание CS1210L

Страница 1: ......

Страница 2: ...ord when disconnecting the charger 8 Make sure cord is located so that it cannot be stepped on tripped over or otherwise subjected to damage or stress 9 Study all the battery manufacturers speci c pre...

Страница 3: ...not over ll For a sealed battery or a battery without cell caps carefully follow manufacturers recharging instructions e Study all battery manufacturers speci cations such as removal of cell caps duri...

Страница 4: ...o the charger The charger output depends on the condition of the battery it is charging When the battery is fully charged the Good will indicate and battery indicator will show 100 then the charger wi...

Страница 5: ...ry indicator light will ash which means charging has not been initiated to initiate charge on a battery that is below 2 0 volts you must fool the battery charger circuitry by momentarily jumping the d...

Страница 6: ...ed to standard battery mode GEL VRLA SLA correctly connect the charger output leads Red Black to battery positive and negative 2 AGM MODE AC Power is connected with the wall socket properly Press MODE...

Страница 7: ...2V 6Amp MAX output 72 Watt 5 LOW TEMPERATURE CHARGING MODE When the ambient temperature is below 10 degrees Press MODE Key The LCD signal will show this mode can be set for battery charging to facilit...

Страница 8: ...LCD Signal INDICATION 1 Pd lead acid battery charging mode...

Страница 9: ...with the wall socket properly Press MODE Key for 3 5 seconds The device will enter DC adapter mode The LCD signal will show DC It can supply 120 Watt output 12V DC 10 Amp 3 Battery tester Mode The cha...

Страница 10: ...battery is worn out or is possibly defective Suggest replacing with a new battery The charger is charging but the 20 100 signal does not come on A The battery is worn out or is possibly defective Sugg...

Страница 11: ...y constant current taking the battery up to 80 of its full capacity 4 Adaptive Phase The charger can make a calculated guess for the battery capacity Automatically adjust the charging current to avoid...

Страница 12: ...battery to recover prior to bulk charge 2 Bulk Charge Phase With the battery now having been activated and gone through the Soft Start phase as needed the bulk charge phase gives the battery constant...

Страница 13: ...Protection Yes Short Circuit Protection Yes Spark Proof Yes Cooling Natural Operating temperature 10 50 C Fuse Protected Cables 10A Waterproof IP64 Battery Capacity Charging and maintenance all 30 300...