background image

CS Instruments 

- 2 - 

 

Contents 

 

1.  Operating principle 
2.  Technical data 
3.  Scope of delivery 
4.  Operation of instrument 
5.  Typical applications 

 
 
I

mportant information 

 

The operating instructions must be read in full and carefully observed 
before starting up the device. 
 
The manufacturer cannot be held liable for any damage which occurs as a 
result of non-observance or non-compliance with this manual. 
 
Should the device be tampered with in any manner other than a procedure 
which is described and specified in the manual, the warranty is cancelled 
and the manufacturer is exempt from liability. 
 
The device is destined exclusively for the described application. 
 
CS Instruments GmbH offers no guarantee for the suitability  for any other 
purpose and is not liable for errors which may have slipped into this 
operating manual. They are also not liable for consequential damage 
resulting from the delivery, capability or use of this device. 
 

 

Содержание LD 300

Страница 1: ...INSTRUCTION MANUAL V2 01 2007 LD 300 Leak Detector For leak detection in pneumatic systems...

Страница 2: ...on compliance with this manual Should the device be tampered with in any manner other than a procedure which is described and specified in the manual the warranty is cancelled and the manufacturer is...

Страница 3: ...l to confirm a diagnosis on the spot by being able to clearly discriminate among various equipment sounds This is accomplished by an electronic process called heterodyning that accurately converts the...

Страница 4: ...istance Frequencies below and above are cut in order to minimize the noise level Scope of delivery Description Order No LD 300 Leak Detector set consisting of 0601 0103 LD 300 Leak Detector 0560 0102...

Страница 5: ...on about 4 hours with LASER pointer on Charging time around 1 5 hour Charging operation temp 10 C to 45 C recommended Operating temperature 0 C to 40 C Storage temperature 10 C to 50 C Weight 2 5 kg...

Страница 6: ...sec all LCD segments are on LD 300 is switched off LD 300 is switched on LCD all segments on for 2 sec Laser off Press Press Press after 30 minutes the appliance switches off The user can adjust the s...

Страница 7: ...With all operating equipment most leakage and electrical problems produce a broad range of sound The high frequency ultrasonic components of these sounds are in nature extremely short wave A short wa...

Страница 8: ...s at insulations Insulation test on doors and windows gas leaks in general Leak detection in compressed air systems Compressed air is one of the most expensive energy forms Only in Germany 60 000 pneu...

Страница 9: ...ose up detection the sensor unit can be removed from the main unit In the scope of delivery there is an extension cable which can be connected between sensor and main unit Detection of leaks in unpres...

Страница 10: ...is is also the case if the serial number has been changed damaged or removed The warranty time for the LD 300 is 12 months for the instrument 6 months for accessory parts Warranty services do not exte...

Страница 11: ...ssories CS Instruments GmbH as the manufacturer herewith declares that the above instruments and accessories belongs to the category 9 WEEE 2002 96 EC Therefore the above instruments do not fall upwar...

Страница 12: ...uth Zindelsteiner Str 15 D 78052 VS Tannheim Tel 49 0 7705 97 89 9 0 Fax 49 0 7705 97 89 9 20 info cs instruments com www cs instruments com Sales office North Am Oxer 28c D 24955 Harrislee Tel 49 0 4...