Troubleshooting
PRESSURE DROP
Sediment pre-filter clogged
o
Replace filter
HIGH BACTERIA COUNT
Check if quartz sleeve stained or dirty
o
Clean quartz sleeve
Check feed water quality
o
Test source water to ensure water quality still within allowable limits
Possible finer sediment in source water than pre-filter capability
o
Test source water for turbidity – may need better pre-filtration
HEATED PRODUCT WATER
Infrequent use of water
o
Run water until it returns to ambient temperature
CLOUDY WATER
Air in lines
o
Run water until air is purged
UNIT LEAKING WATER
Check inlet/outlet fittings correctly installed
Check quartz sleeve o-ring properly fitted.
o
Replace if damaged
o
Clean if dirty
LAMP NOT TURNING ON
Check light on ballast
o
Red means lamp and/or ballast has failed. Replace lamp and check. If still
not working, replace ballast as well.
Check lamp connection