Crystal Vision
Troubleshooting
11 Troubleshooting
Card edge monitoring
The front edge of the card provides useful power rail monitoring, input status and
aspect ratio information.
SYN 3G/SYN-A 3G
front edge view
The following table summarises the card edge LED functions and colours:
Name
LED
Colour
Function when ON
Function when Off
PSU
Green
Good power supply (PSU) rails
One or more of the monitor
supplies is out of specification
HD
Yellow
Video input standard is HD (High
Definition)
Input not present
SD
Yellow
Video input standard is SD
(Standard Definition)
GPO5
Yellow
GPO5 active / low
GPO5 inactive / high
GPO6
Yellow
GPO6 active / low
GPO6 inactive / high
Ref
Yellow
Valid external reference detected
No external reference
The card edge LEDs and 10-digit display may be used in conjunction with status
information from any connected remote status panel display or from VisionWeb if
available.
Board edge control was removed from SYN 3G and SYN-A 3G in 2018. Therefore the
card edge control information is only relevant for older versions of the product.
SYN 3G/SYN-A 3G User Manual R1.3
43
9 July 2019