Crystal Vision
Statesman
Smart Switch 3G User Manual R1.10
37
01/09/2016
Setting delay
The four sliders labelled Alarm Delay Video Black, Alarm Delay Video Frozen, Alarm Delay
Audio Silence and Switch-Back Delay may be adjusted to obtain a delay of 2 - 60 seconds.
The variable assigned is always shown in the top line of the slider display. It is not possible to
assign a delay beyond the range indicated by the slider. If a value less than the minimum or
greater than the maximum is assigned, the slider will automatically jump to the minimum or
maximum value.
The delay controls may be set in several different ways. The slide can be clicked and dragged,
the numerical display may be edited, or a click on a position on the scale will cause the slider
to jump to the value associated with the position that was clicked.
GPI control
The GPI control tab allows the versatile GPI I/O to be configured for the required application.
See section 2.3 for further information about GPIs.
GPI configuration
The GPI inputs can be used to control input selection/routing and are configurable for either
edge or level trigged. They can also be used to give a tally of the selection/routing. When GPI
control is selected to ‘level’, GPI = High (floating) selects Input 1 and GPI = Low (pulled to
ground) selects Input 2.
See page 7 for information on the GPI modes which can be selected.