Crystal Vision
Installation
SNMP
The Indigo 4SE CoolFlow front panel uses the Net-SNMP agent which uses one or more
configuration files to control its operation and the management information provided. The
SNMP window provides a list of these config files. An in-depth explanation can be found by
following the link from the SNMP window.
SNMP window
2.6 SNMP agent
The Indigo 4SE CoolFlow frame comes with a pre-installed SNMP agent that can either
report the status or generate traps on a status change of the PSU and frame systems. These
SNMP traps can then be used to trigger alarms – for example, when a signal has been
removed, the video standard changed or any of the many monitored status variables change.
Note:
It will be necessary to import the frame MIB into the SNMP manager. See the manager
instructions if necessary to accomplish this.
Management information base (MIB)
As is normal for an SNMP manager system, each board to be monitored (in this case the
front panel) has an associated MIB. Each MIB is a collection of object identifiers that
identify all variables that can be read via SNMP.
The following diagram gives an overview of the OID sequences within the MIB tree.
Indigo 4 CoolFlow User Manual R1.7